background image

 

       

 

 

 

 

 

 

 

 

18

Titan CPU Channel Mul  plexer - Notes

Notes & Known Issues

Addi  onal informa  on about the CPU not covered elsewhere:

 

Error Indica  ons:

 

If a Titan Input Device (Mini-Recorder or Pod) stops sending data for any reason, the

 

CPU will stop recording/stop scanning and display an error (the ERR LED will be ON).

 

CPU Power Loss/Data Loss:

 

1.  In the event of a power loss while recording remotely to the CPU, data loss is limited 

 

to 10 seconds maximum.

 

2.  If the CPU loses power while scanning, all independently-powered Titan Input

 

Devices (Mini-Recorders or Pods) must be power-cycled in order to resynchronize the  

 

system.

 

CPU Remote Recording:

 

The CPU does not automa  cally handle Pod confi gura  on changes made since the

 

last remote recording (for example, if Pods are swapped between ports, or if a Pod is

 

removed and used for another test, and then reconnected to the CPU). If a change

 

occurs between tests, connect to TCS and run a short test to reconfi gure the CPU and all

 

connected Pods prior to resuming remote recording.

 

Remote Switch Opera  on:

 

If the Remote Switch is connected to the CPU and switched ON, the CPU will a  empt

 

to record repeatedly even if no pods are connected or an error condi  on exists. Each

 

a  empt will generate a small data fi le on the CPU. These fi les are invalid.

 

Mini-Recorder/Pod Reconfi gura  on

 

When a Mini-Recorder or Pod is connected to the CPU, the baud rate on the COMM

 

port is reset to 3Mbits. Remote recording func  onality on Mini-Recorders is also

 

disabled (this includes both the front panel switch and the REM jack on the Mini-

 

Recorder). The default baud rate and remote recording capability is restored on Titan

 

Mini- Recorders a  er running a test directly from TCS.

Summary of Contents for CPU04

Page 1: ...Titan CPU Channel Multiplexer CPU04 CPU08 CPU12 User Manual...

Page 2: ...ual is copyright 2020 All rights reserved Brief excerpts may be made from this manual for technical purposes as long as they are referenced Although this manual is believed to be correct at the me of...

Page 3: ...roduc on Opera on Interface Connec ons Front Panel Rear Panel Connec on Diagram REM Remote Titan Input Module Ports 4 4 5 6 8 9 10 11 12 Features Speci ca ons 15 Warranty Repair 17 Changing the IP Add...

Page 4: ...directly to an SD memory card or to a host PC and network opera on is possible via TCP IP or UDP This manual is intended to provide the user with an overview of the Titan CPU Channel Mul plexer with...

Page 5: ...ickup All of the analog inputs of the Titan hardware have a return path to ground However it is very important that each sensor have only one return path to avoid ground loops When tes ng a vehicle o...

Page 6: ...Channel Mul plexer front and rear panels appear below The Titan CPU front panel incorporates a power connector and switch LED status indicators an Ethernet port a Programming PGM port and a jack for...

Page 7: ...Adapter furnished with the Titan CPU is su cient to power the CPU and approximately eight Input Modules with no excitation If using the CPU12 with more than eight modules connected or if excitation is...

Page 8: ...Mul plexer Opera on Rear Panel The rear panel on all three Titan CPUs incorporate RJ 45 Input Module connectors LED indicators for each four port group and a Sync jack CPU04 Rear Panel CPU08 Rear Pan...

Page 9: ...of which includes a Digital Pod Connec ons between the CPU and the Titan Input Modules are made using standard straight through CAT6 Ethernet cables The maximum recommended cable length from the Mini...

Page 10: ...hen the CPU is recording Titan Input Module Ports The Titan CPU has twelve iden cal Titan Input Module Port connectors LEDs integrated into these connectors indicate when a connected Titan Input Modul...

Page 11: ...11 Titan CPU Channel Mul plexer Interface This page inten onally le blank...

Page 12: ...power to the CPU 3 Using standard Ethernet cabling make the connec ons to the Titan CPU Use Cat6 Ethernet cable for connec ons to input modules and Cat5 cable for connec on to the LAN Cable lengths to...

Page 13: ...he PC to 192 168 10 61 For instruc ons on changing the PC IP address refer to h ps support microso com en us help 15089 windows change tcp ip se ngs 2 With the sta c address changed on the PC and with...

Page 14: ...Scan The green SCN LED will illuminate when the CPU is scanning REC Record The red REC LED will illuminate when the CPU is recording either under control from TCS or from the Remote Switch Remote Swi...

Page 15: ...total plus digital channels CPU08 Up to eight 16 channel Titan Input Modules 128 analog channels total plus digital channels CPU12 Up to twelve 16 channel Titan Input Modules 192 analog channels total...

Page 16: ...ue use the increment decrement controls or manually enter the desired value in the number eld The index value can also be reset by issuing a manual command in the TCS Manual Command window func on key...

Page 17: ...y purchased This warranty will be void if unauthorized altera ons or modi ca ons are found which impede the repair or tes ng of the equipment Warranty The equipment should be tested as soon as it is r...

Page 18: ...if Pods are swapped between ports or if a Pod is removed and used for another test and then reconnected to the CPU If a change occurs between tests connect to TCS and run a short test to recon gure th...

Page 19: ...19 Titan CPU Channel Mul plexer Notes...

Page 20: ...Mars Labs LLC 29 C Street Laurel Maryland 20707 301 470 3278 www marslabs com...