SOLO-KC
INSTALLATION MANUAL
Page 16
9.5.1
SPO parameter
Parameter is used to define the starting point on the SIM card from where toward the parameters are
written.
NOTE
This parameter is only used when programming is done via SMS or directly over USB
connection. This parameter must be send first before other parameters.
9.5.2
LOT parameter
LOT parameter is used to define the time out control for voice calls. The start of voice connection
starts the LOT timer. If the voice connection is still ON when the LOT timer expires SOLO-KC
disconnects ongoing voice connection.
9.5.3
#0 parameter
Parameter is used to define head of the SMS message. It is used by the user to uniquely define the
name of the SOLO-KC device. This name will be put in front of every SMS the user will receive.
NOTE
The text for a name if written together with the parameter name.
Example:
#0
DEMO
9.5.4
Table of parameters
Name
Comment
UDC
Tel. number of SOL KC device
RAN
Auto answer ring number
HTN
Hidden telephone number
TST
SMS test time out
TSTT
Periodic test SMS start time
MNF
Manual GSM provider selection
MIC
Microphone volume control
SPK
Speaker volume control
ARST
Time out control for automatic system restart
ADF
Auto dial functionality ( Call TN1 )
LNG
Language selection
BUZ
Buzzer control
LOT
Voice time out control
#0
Unique name for SMS reporting
Table 10: Set-up parameters.