045%0DQWHO&OHDUDQFHV
Before installing any mantels it is important to determine the combustibility of its
material(s). There are two types of mantels to consider: Combustible and Non-
Combustible.
A
&RPEXVWLEOH0DQWHO
is one that consists of material(s) that may discolor,
combust, or lose its integrity in the presence of heat. These types of mantels
must strictly conform to the dimensional requirements shown below.
Conversely, a
1RQ&RPEXVWLEOH0DQWHO
is one that is constructed with material(s)
that will not combust. Check your local codes and regulations to determine whether your mantel is Combustible or Non-Combustible.
The advantage to Non-Combustible Mantels is that it may extend right up to the tile lip of the fireplace. Combustible mantels must
adhere to the dimensional restrictions shown below.
&OHDUDQFHWR&RPEXVWLEOHV045%
Front
24”[61cm]
Back Shield Kit to Wall
0” [0cm]
Side (from Stand-offs)
0” [0cm]
Floor
0” [0cm]
Airbox on Flue Side of Unit
1” [25cm]
Minimum Ceiling Height (from bottom of fireplace)
60
”
[153cm]
Top (from Stand-offs)
0” [0cm]
Top of 90° Bend under 72
” Enclosure
5”
(With Wall Thimble Shield
[Z57WTS]) All Vent Systems
Top of 90° Bend over 72
” Enclosure
4”
All Vent Systems
Top of Horizontal Pipe
2” All Vent Systems
Side & Bottom of Horizontal Pipe
1” All Vent Systems
Vertical Vent Pipe
1” All Vent Systems
Vertical Vent Pipe
1”
DuraVent-DirectVent Pro /
AmeriVent / Selkirk Direct Temp
Systems
Mantel Dimensions are
from front face or Non-
Combustible Facing
Materials covering
fireplace.
[Steel Stud Framing Shown.]
1RWH
If appliance is installed
directly on carpeting or other
combustible material other than
wood flooring, a metal or wood
panel extending the full width
and depth of the appliance must
be used. Carpet may extend 1
inch above the floor of the
appliance.
&RPEXVWLEOH2EMHFWVRQ1RQ
&RPEXVWLEOH0DQWHO:DUQLQJ
Combustible objects must not be placed
on a Non-combustible Mantel unless the
mantel meets the dimensional
requirements for a Combustible Mantel.
Refer below to determine whether your
mantel conforms to the requirements of
a Combustible Mantel.
6WHHO)UDPLQJ6WXG
32