
8
“CMP” & “C” Series Automatic Water Conditioners
General Operation
When the system is operating one of two displays will
be shown. Pressing NEXT will alternate between the
displays. One of the displays is always the current time
of day which has to be set (see pg.9). Capacity
remaining is the number of gallons that will be treated
before the system goes through a regeneration cycle.
The user can scroll between the displays as desired.
If the system has called for a regeneration that will occur
at the preset time of regeneration, the words REGEN
TODAY will appear on the display.
When water is being treated (i.e. water is flowing through
the system) the word “Softening” or “Filtering” flashes on
the display.
User Displays/Settings
REGEN
TODAY
SOFTENING
CAPACITY
REMAINING
GAL
REGEN TODAY will
show if a regeneration
is expected “Tonight.”
TIME
SET
CLOCK
NEXT
REGEN
650
REGEN
TODAY
SOFTENING
PM
SET
CLOCK
NEXT
REGEN
6:35
Installer Displays/Settings
STEP 1
- Press NEXT and simultaneously for 3 seconds.
STEP 2
- Hardness: Set the amount of hardness in grains of hardness as
calcium carbonate per gallon using the or buttons. Value ranges from
1 to 150 in 1 grain increments. Note the grains per gallon can be increased if
soluble iron needs to be reduced. This display will show
“-nA-” if “FILTER” is selected or if ‘AUTO’ is not selected. Press NEXT to go to
step 3. Press REGEN to exit Installer Displays/Settings.
STEP 3
- Day Override: When gallon capacity is set to off, set the number
of days between regenerations. When gallon capacity is set to AUTO or to a
number, set the maximum number of days between regenerations. If value set
to “oFF” regeneration initiation is based solely on gallons used. If value is set as
a number (allowable range from 1 to 28) a regeneration initiation will be called
for on that day even if sufficient number of gallons were not used to call for a
regeneration. Set Day Override using or buttons:
•
number of days between regeneration (1 to 28); or
•
“oFF”
Press NEXT to go to step 4. Press REGEN to return to previous step.
STEP 4
- Next Regeneration Time (hour): Set the hour of day for regeneration
using or buttons. AM/PM toggles after 12. The default time is 2:00
a.m. This display will show “REGEN on 0 GAL” if “on 0” is selected in by the
installer. Press NEXT to go to Step 5. Press REGEN to return to previous step.
STEP 5
- Next Regeneration Time (minutes): Set the minutes of day for
regeneration using or buttons. This display will not be shown if “on
0” is selected by the installer (2 a.m. is the factory setting). Press NEXT to exit
Installer Displays/Settings. Press REGEN to return to previous step.
To initiate a manual regeneration immediately, press and hold the “REGEN”
button for three seconds. The system will begin to regenerate immediately.
The control valve may be stepped through the various regeneration cycles by
pressing the “REGEN” button.
RETURN TO
NORMAL MODE
REGEN
SET TIME
A.M.
REGEN
SET TIME
A.M.
REGEN
DAY
SET
SET
CLOCK
NEXT
REGEN
Step 1
SET
HARDNESS
Step 2
SET
CLOCK
NEXT
REGEN
20
SET
HARDNESS
Step 3
SET
CLOCK
NEXT
REGEN
14
Step 4
SET
CLOCK
NEXT
REGEN
2:00
Step 5
SET
CLOCK
NEXT
REGEN
2:00
8-171 R5