44
CV
Explanation
Values
Default
Notes
64
Threshold for brake squealing
1 - 255 (0 - 63)*
{x4}*
9
The higher the value the sooner the
squealing begins, the lower the value
the later the squealing begins. If
the value is too low, no squealing is
activated.
73
Storing different states:
Bit 0: storing function states
Bit 1: storing speed
Bit 2: starting up with/without ABV after a reset
0 - 7
0 / 1
0 / 2
0 / 4
7
0 = do not store / 1 = store
0 = do not store / 2 = store
0 = without ABV / 4 = with ABV
74
Storing different states:
Bit 0: storing direction of travel
0 - 1
1
0 = do not store / 1 = store
75
Address 2 (1st consecutive address)
1 - 80
60978=73
60979=25
Address can be activated/deactivated
subject to CV 49.
76
Analog DC startup voltage
1 - 63 {x4}*
12
Note for CS1: (140)
The CS1 shows this value inverted.
77
Analog DC maximum speed
1 - 63 {x4}*
43
78
Analog AC startup voltage
1 - 63 {x4}*
15
Note for CS1: (140)
The CS1 shows this value inverted.
79
Analog AC maximum speed
1 - 63 {x4}*
49
CV Table for fx (MM)
* () = 6021 Control Unit {} = the values entered are multiplied times “x” (factor).