20
Configuration of the Outputs
(For switching functions, see page 22)
CV
Meaning
Value
Comment
112 POM Switching Function Turnout 1, red
0 – 18
Switches the “red“ output for the first turnout
113 POM Pulse Width
0 – 255
255 = 100 %
114 POM Period
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
115 POM Switching Function Turnout 1, green
0 – 18
Switches the “green“ output for the first turnout
116 POM Pulse Width
0 – 255
255 = 100 %
117 POM Period
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
118 POM Switching Function Turnout 2, red
0 – 18
Switches the “red“ output for the second turnout
119 POM Pulse Width
0 – 255
255 = 100 %
120 POM Period
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
121 POM Switching Function Turnout 2, green
0 – 18
Switches the “green“ output for the second turnout
122 POM Pulse Width
0 – 255
255 = 100 %
123 POM Period
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
124 POM Switching Function Turnout 3, red
0 – 18
Switches the “red“ output for the third turnout
125 POM Pulse Width
0 – 255
255 = 100 %
126 POM Period
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
127 POM Switching Function Turnout 3, green
0 – 18
Switches the “green“ output for the third turnout
128 POM Pulse Width
0 – 255
255 = 100 %
129 POM Period
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
Summary of Contents for 60831
Page 1: ...Weichendecoder m83 60831 1 2 3 4 5 6 7 8 9 10 ON F D GB USA NL ...
Page 13: ...13 ...
Page 23: ...23 ...
Page 33: ...33 ...
Page 43: ...43 ...
Page 45: ...Weichendecoder m83 60831 1 2 3 4 5 6 7 8 9 10 ON S DK ...
Page 57: ...13 ...
Page 67: ...23 ...
Page 77: ...33 ...
Page 87: ...43 ...