24
APPLICATION INSTRUCTIONS
Application Instructions for Total Concept Descaler Cleaning of the Boiler
Size: Case of 4 -1 Gallon Bottles / Part No. 20-0307 or 1-1 Gallon Bottle / Part No. 20-0307X
GENERAL NOTES:
Market Forge R has two basic types of boilers;
one has an automatic drain valve, the other has
a manual drain valve. To determine which type
you have, open cabinet doors and you will see a
control box with two switches and an indicator
light. The instruction label on the control box will
identify the boiler as being either automatic or
manual. Those boilers designated as being
automatic must be energized in order to close
the drain valve.
Total Concept is designed to be used with water
between 160°F to 200°F.
Preheating is required on both automatic and
manual boilers to raise the water temperature to
the acceptable range. (
160°F to 200°F
).
For manual boilers, make certain drain valve is
tightly closed.
On Market Forged boilers manufactured after
8/84; your unit is equipped with an access plug
in the steam header line. This location should be
used to add cleaner/descaler to boiler chamber
during maintenance.
On Market Forged boilers manufactured before
8/84; access to boiler chamber should be gained
through either the vent-rite or the pressure
relief valve.
Total Concept is a NSF listed nonfood product.
This is a liquid acid (nonmuriatic) product that
works without fumes, odors, and hazards
associated with other harsh chemicals.
BOILER TREATMENT CLEANING INSTRUCTIONS:
After
determining
proper
location
for
cleaner/descaler to be added: Read complete
instructions thoroughly; including all warning
and cautionary statements.
Figure 1
1. Energize boiler and fill to operating level.
Figure 2
2. Energize heating circuit to pre-heat unit.
Figure 3
Figure 4
3. AUTOMATIC - After unit is pre-heated, cycle
the power switch to the OFF position then
immediately back to the ON position.
S-2299