INSTALLATION INSTRUCTIONS
GAS OPERATED BOILERS
MODELS:
• M24G100A - 4SP
• M24G200A - 4SP
• M36G100A - 4SP
• M36G200A - 4SP
• M36G300A - 4SP
CAUTION: BE SURE TO READ:
Keep this appliance area free and clear from combustibles.
Do not obstruct the flow of combustion and ventilation air.
Keep this manual for future reference.
This installation must conform with local codes, or in the absence of local codes, with the
National Fuel Gas code, ANSI Z223.1-Latest Edition. For installation in Canada, this appliance is
to be in accordance with the current CAN/CGA-B149 (.1 or .2) Installation Code for Gas Burning
Appliances and Equipment and/or Local Codes.
This appliance, when installed, must be electrically grounded in accordance with local codes, or
in the absence of local codes, with the National Electric Code, ANSI/NFPA70-Latest Edition. For
installation in Canada, All electrical connections are to be made in accordance with CSA C22.1
Canadian Electrical Code Part 1 and/or Local Codes.
The boiler and its individual shut off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressure in excess of 1/2 PSI (
0.03
kg/cm
2
).
The boiler must be isolated from the gas supply system by closing its individual manual shut off
valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than 1/2 PSI (
0.03 kg/cm
2
).
The wiring diagram label is located on the inside of the Lift-Off Front Panel.
This product must be installed in a room with adequate air supply.
Do not place any objects on or directly against the unit as to block air openings into the
combustion chamber.
Clearances from both combustible and non-combustible construction are 3” (
76mm
) from
sidewalls, 6” (
152mm
) from rear wall. With lower deflector plate, shown on page 4, installed this
unit is suitable for Installation on Combustible Floors.
This unit is serviceable from the front, do not install in such a manner where a service person
cannot remove front panels.
INSTALLING LEGS:
Some models are shipped without legs. A separate carton will contain the legs. If your model is received
this way, be sure to follow the installation instruction sheet packed with the legs.
LEVELING:
In order for the boiler to drain correctly, it is important to use a level on cabinet top both left and right
and front-to-back. If not level, adjust feet. On compartment cookers, check the interior shelves for level
condition.
LOWER DEFLECTOR PLATE:
The lower deflector plate must be installed on the boiler. Be sure to follow the installation instructions
located on page 4.