background image

4

INSTALLATION

Installation Instructions

1.  These kettles must be installed on a suitable table or 

counter top.

2.  On counter top make the following holes. Provide suf-

ficient space from rear wall to allow for tilting of kettle.

a.  7/8” holes at 13 - 3/4” center for kettle legs on 

models FT-6, FT-10, and FT-12

b.  23-1/2” center on model FT-20. 

3.  From bottom of leg remove mounting lockouts and 

washers. Apply Silastic to flared edge of leg. Insert 

threaded portion of legs through holes. Replace 

washers and locknuts and tighten. Wipe off excess 

sealant.

4.  Install a safety relief valve in the steam line set at the 

maximum operating pressure of the kettle. Note that 

one valve will handle a series of kettles.

5.  Connect steam supply line (1/2” pipe size) to steam 

inlet fitting on right leg.

6.  Install a steam shutoff valve in steam supply line, 

preferably near the kettle for convenience.

7.  A pressure reducing valve will be required if the steam 

supply pressure is greater than the maximum kettle 

working pressure.

8.  If large amounts of water are in the steam line it will 

be necessary to install one or more ball float traps in 

the line to eliminate the water.

9.  A steam line pressure gauge is also recommended 

to determine the actual amount of steam coming to 

the kettle.

10. Install a suitable steam trap in condensate line (left 

leg) near the kettle and run condensate return line to 

drain. If the condensate return line will be directed to 

the boiler, then it must have a check valve and gate 

shutoff valve near the kettle.

Summary of Contents for FT Series

Page 1: ...T SERIES DIRECT CONNECTED STEAM KETTLE INSTALLATION OPERATION MAINTENANCE Telephone 802 658 6600 Fax 802 864 0183 www marketforge com PN 14 0337 Rev C 3 17 2017 Market Forge MODELS FT 6 FT 10 FT 12 FT 20 ...

Page 2: ...Your Service Agency s Address Model Serial number Oven installed by Installation checked by ...

Page 3: ...s equipment FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liq uids in the vicinity of this or any other appliance The information contained in this manual is important for the prop er installation use and mainte nance of this oven Adherence to these procedures and instruc tions will result in satisfactory baking results and long trou ble free service Please read this ma...

Page 4: ...N WILL BE BY Direct steam at a minimum of 5 PSI 0 4 kg cm2 and a maximum of 50 PSI 3 4 kg cm2 FUNCTIONING MODE Direct connected steam jacketed kettles consist of a stainless steel bowl and a stainless steel jacket which en velopes two thirds of the lower surface of the bowl thus forming a sealed pressure vessel chamber into which steam is introduced by means of a manual control valve located in th...

Page 5: ...60 4 88 124 35 12 892 0 0 19 25 489 FT 20 21 533 18 457 26 5 673 23 5 597 1 5 38 6 25 159 24 12 613 15 25 387 15 75 400 10 5 267 40 5 1029 7 5 191 11 12 283 42 38 1076 1 5 38 26 660 G Q E FT 6 FT 10 FT 12 G E Q FT 20 G E Q B ØA D CR S M N H C O POUR PATH F P K J MIN L SERVICE CONNECTIONS S Steam Supply 1 2 13mm IPS 15 50 PSI 1 0 3 5 kg cm2 Pressure reducing valve is required if incoming pressure e...

Page 6: ...t one valve will handle a series of kettles 5 Connect steam supply line 1 2 pipe size to steam inlet fitting on right leg 6 Install a steam shutoff valve in steam supply line preferably near the kettle for convenience 7 A pressure reducing valve will be required if the steam supply pressure is greater than the maximum kettle working pressure 8 If large amounts of water are in the steam line it wil...

Page 7: ...cause pitting and corrosion when used over a period of time this will reduce the life of the appliances Should pitting or corrosion occur this is not covered by warranty Follow the recommended cleaning instructions Use a mild detergent warm water and rinse thoroughly PREVENTATIVE MAINTENANCE No preventive maintenance is required other than adher ing to the Cleaning Procedure instructions Safety Va...