background image

2

INSTALLATION

Introduction

GENERAL:

All direct connected steam jacketed kettles pertaining to 

this manual are direct steam operated pressure vessels 

of a double-wall stainless steel construction forming a 

steam chamber (jacket) enveloping the lower two thirds 

of the kettle bowl surface. All kettles are tilting and coun-

tertop mounted in fixed positions on legs.

Available models include: 

• 

FT-6

, 6-Gallon (23 liters)

• 

FT-10

, 10-Gallon (38 liters)

• 

FT-12

, 12-Gallon (46 liters)

• 

FT-20

, 20-Gallon (76 liters)

DESCRIPTION:

Kettle  will  be  constructed  of  welded  satin  finish,  stain-

less steel type 304. A double wall kettle interior will form 

a steam jacket around the lower 2/3 of the kettle. Kettle 

bottom will be of elliptical design for improved heat circu-

lation.
Type 316 stainless steel liner for high acid content prod-

ucts. Tubular stainless steel mounting frame will have 

steam supply and condensate return pipes completely 

concealed within frame members.
Sealed stainless steel tilt mechanism bearings will per-

mit the kettle to tilt forward 90o for complete emptying. A 

removable operating handle with heat-proof knob can be 

mounted on the left or right side of each kettle. Kettle will 

be built to A.S.M,E. code and will be N.S.F. approved.

OPERATION WILL BE BY:

Direct steam at a minimum of 5 PSI (0.4 kg/cm2) and a 

maximum of 50 PSI (3.4 kg/cm2).

FUNCTIONING MODE:

Direct connected steam jacketed kettles consist of a 

stainless steel bowl and a stainless steel jacket which en-

velopes two thirds of the lower surface of the bowl thus 

forming a sealed pressure vessel (chamber) into which 

steam is introduced by means of a manual control valve 

located in the right leg.
The kettle bowl is the container for the food product which 

ideally should be of a liquid or semiliquid consistency to 

achieve complete contact with the bowl surface and thus 

fully absorb the heat transmitted through that surface.
The  temperatures  required  for  the  cooking  process  to 

function adequately must be greater than the boiling point 

of the liquid food product, viz. water. Further, the greater 

the steam pressure used, the higher the temperature and 

consequently the quicker the cooking process. For exam-

ple, steam pressurized at 30 psi attains a temperature of 

274°F (135°C).
In the initial stages of the cooking process when the 

steam comes in contact with the cold kettle bowl surface 

it condenses and forms considerable amounts of water. 

A thermostatic steam trap should be plumbed to the exit 

end of the kettle jacket. This trap is a mechanical device 

that closes on high temperatures and opens when the 

temperature drops thus allowing the water formed from 

condensate to exhaust but retain steam under pressure.

Summary of Contents for FT Series

Page 1: ...T SERIES DIRECT CONNECTED STEAM KETTLE INSTALLATION OPERATION MAINTENANCE Telephone 802 658 6600 Fax 802 864 0183 www marketforge com PN 14 0337 Rev C 3 17 2017 Market Forge MODELS FT 6 FT 10 FT 12 FT 20 ...

Page 2: ...Your Service Agency s Address Model Serial number Oven installed by Installation checked by ...

Page 3: ...s equipment FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liq uids in the vicinity of this or any other appliance The information contained in this manual is important for the prop er installation use and mainte nance of this oven Adherence to these procedures and instruc tions will result in satisfactory baking results and long trou ble free service Please read this ma...

Page 4: ...N WILL BE BY Direct steam at a minimum of 5 PSI 0 4 kg cm2 and a maximum of 50 PSI 3 4 kg cm2 FUNCTIONING MODE Direct connected steam jacketed kettles consist of a stainless steel bowl and a stainless steel jacket which en velopes two thirds of the lower surface of the bowl thus forming a sealed pressure vessel chamber into which steam is introduced by means of a manual control valve located in th...

Page 5: ...60 4 88 124 35 12 892 0 0 19 25 489 FT 20 21 533 18 457 26 5 673 23 5 597 1 5 38 6 25 159 24 12 613 15 25 387 15 75 400 10 5 267 40 5 1029 7 5 191 11 12 283 42 38 1076 1 5 38 26 660 G Q E FT 6 FT 10 FT 12 G E Q FT 20 G E Q B ØA D CR S M N H C O POUR PATH F P K J MIN L SERVICE CONNECTIONS S Steam Supply 1 2 13mm IPS 15 50 PSI 1 0 3 5 kg cm2 Pressure reducing valve is required if incoming pressure e...

Page 6: ...t one valve will handle a series of kettles 5 Connect steam supply line 1 2 pipe size to steam inlet fitting on right leg 6 Install a steam shutoff valve in steam supply line preferably near the kettle for convenience 7 A pressure reducing valve will be required if the steam supply pressure is greater than the maximum kettle working pressure 8 If large amounts of water are in the steam line it wil...

Page 7: ...cause pitting and corrosion when used over a period of time this will reduce the life of the appliances Should pitting or corrosion occur this is not covered by warranty Follow the recommended cleaning instructions Use a mild detergent warm water and rinse thoroughly PREVENTATIVE MAINTENANCE No preventive maintenance is required other than adher ing to the Cleaning Procedure instructions Safety Va...