3
INSTALLATION
Service Connections
DIMENSIONS ARE IN INCHES [MM]
59 [1499]
10.5 [267]
5.88 [149]
G
EC
7.13 [181]
4 [102]
26
[660]
18.38
[467]
19.88 [505]
30.5 [775]
2 [51]
CW
HW
CW OPTIONAL
OPTIONAL
35 [889]
45.5 [1
156]
FLANGED FOOT DETAIL
Ø4 EQUALLY SPACED
7/16 [11] HOLES
ON 3 [75] B.C.
G
Ø30 [762] ID
EC
36.63 [930]
22.63 [572]
18.75 [476]
5.25 [133]
50.25 [1276]
3.5 [89]
6.5 [165]
18.75 [476]
29.63 [752]
40.5 [1029]
OPTIONAL
SPRING ASSIST
COVER
75.25
[1911]
6.25
[177]
22 [559]
CW
39.5 [1003]
OPTIONAL
CW
HW
OPTIONAL
8.25 [210]
27.75 [705]
4 [102]
SERVICE CONNECTIONS
EC Electrical Connection
- 120V, 60Hz, 1pH
with grounding wire, unless other wise
specified. Includes a 6 foot and 3 prong
plug. Total Max Amps: 4.0
G
Gas Connection
- 3/4” (19mm) N.P.T. a
gas shut-off valve must be installed in sup-
ply piping convenient and adjacent to unit.
CW Cold Water
- 3/8” (10mm) O.D. tubing to
optional faucet.
HW Hot Water
- 3/8” (10mm) O.D. tubing to
optional faucet.
BTU/Hour: 120,000
kW/Hour: 35.2
Gas Supply (Supply Pipe Pressure W.C.)
Natural 6”-14” (152-356mm)
Propane 11”-14” (279-356mm)
Minumum Clearance (Sides & Back) :
4” (102mm)
FULLY JACKETED GAS KETTLE
Figure 2