3.5 Outdoor Units’ Printed Circuit Diagram abbreviations
No.
Name
CN#
Meaning
1
Power Sup-
ply
CN3
Earth: connect to Ground.
CN1
N_in: connect to N-line (208-230V AC input).
CN2
L_in: connect to L-line (208-230V AC input).
2
S
CN16
S: connect to indoor unit communication.
3
HEAT1
CN17
Connect to compressor heater, 208-230V AC when
is ON.
4
4-WAY
CN60
Connect to 4 way valve, 208-230V AC when it is ON.
5
HEAT2
CN15
Connect to chassis heater, 208-230V AC when it is
ON.
6
AC-FAN
CN25
Connect to AC fan.
7
TP, T4, T3
CN21/CN22
Connect to pipe temp. sensor T3, ambient temp.
sensor T4, exhaust temp. sensor TP.
8
PMV
CN31
Connect to Electric Expansion Valve.
9
DC-FAN
CN7
Connect to DC fan.
10
TESTPORT
CN6
Used for testing.
11
W
CN28
Connect to compressor.
V
CN29
0V AC (standby).
U
CN30
10-200V AC (running).