8.6.4 Fan Motor Check
1. Turn off outdoor unit and disconnect power supply.
2. Disconnect outdoor fan motor power cord from outdoor PCB.
3. Measure the resistance value between each windings.
The normal resistance values of different fan motor models are as follows:
Fan Motor Model
YKFG-13-4-38L
YKFG-13-4-38L-4
YKFG-15-4-28-1
YKFG-20-4-10L
YKFG-20-4-5-11
Brand
Welling
Welling
Welling
Welling
Black - Red Main
345
Ω
75
Ω
269
Ω
388
Ω
Blue - Black AUX
348
Ω
150
Ω
224
Ω
360
Ω
Fan Motor Model
YKFG-20-4-5-19
YKFG-25-4-6-14
YKFG-28-4-3-7
YKFG-28-4-3-14
YKFG-28-4-6-5
Brand
Welling
Welling
Welling
Welling
Black - Red Main
444
Ω
287
Ω
231
Ω
183.6
Ω
Blue - Black AUX
470
Ω
409
Ω
414
Ω
206
Ω
Fan Motor Model
YKFG-45-4-13
YKFG-45-4-22
YKFG-45-4-22-13
YKFG-60-4-2-6
Brand
Dongfang
Welling
Welling
Black - Red Main
125.2
Ω
168
Ω
96
Ω
Blue - Black AUX
83.8
Ω
141
Ω
96
Ω