background image

18

Recommissioning: 

• 

Perform a visual inspection for damage.

• 

Slowly fill the emptied parts - carefully remove the air.

• 

Open all valves.

• 

Press the main switch.

• 

Turn the system on.

10.2 Disassembly Tanner FBA

1. Turn off the main switch and lock it.
2. Remove the power supply and the electrical 
connection in the junction box.
3. Close the hot water supply.
4. Loosen the screws on position 2 (4x) and remove 
the front wall. 
5. Empty position 5 by opening the discharge pipe.
6. Disassemble the heating medium.
7. Loosen the ceiling screws and remove the unit.
8. Disassemble the rear wall after screws on position 
4 (4x), position 3 (3x) and if necessary position 1 (3x) 
have been removed and remove the engine. 

9. Pull the heat exchanger from the unit.
10. Move both halves by moving vertically.

10.3 Disassembly Tanner FBA Ultra

1. Turn off the main switch and lock it.
2. Remove the power supply and electrical 
connection in the junction box “K”.
3. Close the hot water supply.
4. Disassemble the heating medium.
5. Loosen the ceiling screws and remove the unit.
8. Remove the sheet metal screws 

[1]

 (12x).

9. Remove rear “R” with attached fan, unit is now still 
attached to rear wall.
10. Remove fixing screws 

[2]

 (3x) for heater.

11. Remove the heater and the mounting plates.

Summary of Contents for 0662551

Page 1: ...Technical manual EN MARK TANNER FBA ULTRA 0662551...

Page 2: ...2...

Page 3: ...hat they do not play with the appliance Index 1 Intended use 4 2 Safety 5 3 Receiving of the goods 6 3 1 Damage in transport 6 3 2 Transport packaging 6 4 Mounting 6 4 1 Ceiling mounting 6 4 2 Mountin...

Page 4: ...are suitable for Transport of air that is Dust free Without harmful substances Non agressive Non corrosive Not flammable Purification of air for Filtering Heating Cooling Consultation with or consent...

Page 5: ...stopped The components have been cooled down to room temperature Note Only qualified personnel should perform maintenance on the electrical components Consider the local regulations Changes or additi...

Page 6: ...4 1 Ceiling mounting Fastening the FBA device to the ceiling must be done with officially approved fasteners In the dimensioning of the fastening the following gear weights should be taken into accoun...

Page 7: ...on the outside to prevent condensation 4 3 Roof mounting The mounting of roof accessories raincover or channels can be performed at the scene Slabs are not included 4 4 Louvre adjustment When adjustin...

Page 8: ...heat exchanger When decommissioning the frost protection thermostat should be connected to the air outlet side of the heat exchanger 4 6 Air valve and drain valve When using an air valve you must mak...

Page 9: ...ing unit 685 52 54 E TK Thermocontact TK Thermocontact Fan engine 1 Fan engine 2 o X TK Thermocontact TK Thermocontact Fan engine 1 Fan engine 2 o X Switching unit 685 55 58D 683 56D 58D 7 wire 7 wire...

Page 10: ...5 685 55D 5 2 1 685 56D 10 4 2 685 57D 20 8 5 685 58D 35 14 10 5 wire 5 wire 9 wire 4 wire 4 wire 9 wire RT Room thermostat TK Thermocontact RT Room thermostat TK Thermocontact Location supply fuses...

Page 11: ...ocontact Location supply fuses 1 U 2 U 11 685 54E 12 14 N L L RT RT 250 V AC max 2A 250 V AC max 1A RT FS FS TK TK L1 N FS TK M 1 1 U 2 U 11 685 52 53E 12 14 1 2 3 6 7 250 V AC max 2A 250 V AC max 1A...

Page 12: ...ostat and actuator on off 517 Switching unit Position 0 Servomotor Position Closed Position 0 Servomotor Position Closed 13 14 21 22 13 14 21 22 707 OPEN CLOSE N 14 12 671 N 685 54 E 685 55 58 D 1 2 6...

Page 13: ...will end the warranty of the engine Important switching capacity 10 A with cos 1 0 6 A with cos 0 6 Voltage 250 V Voltage power 2000 V eff If the engine protection is in operation the engine can only...

Page 14: ...of engines switches and other electrical accessories should be done in accordance with the relevant standards VDE 0100 EMC act rules of RU For speed control a frequency converter cannot be used since...

Page 15: ...ordance with the technical data The condensate pump lies in the drip tray In the inlet of the pump a round filter has been inserted See figure 2 The condensate pump is designed for continuous use For...

Page 16: ...he filter must definitely be cleaned or if necessary replaced In the abscence of maintenace the warranty expires 9 Maintenance 9 1 Warranty Our warranty does not cover damage caused by improper use or...

Page 17: ...the heat exchanger by blowing compressed air onto it Take care of oil containing dust with an oil soluble detergent Use a steam cleaner to remove sticky surface Note Use low pressure as well as an in...

Page 18: ...g screws and remove the unit 8 Disassemble the rear wall after screws on position 4 4x position 3 3x and if necessary position 1 3x have been removed and remove the engine 9 Pull the heat exchanger fr...

Page 19: ...er cables must be removed by a qualified electrician More over all fluid carrying parts must be completely empty This must be done by a professional company that properly draines the water with anti f...

Page 20: ...ELGIQUE TELEFOON 32 0 3 6669254 FAX 32 0 3 6666578 info markbelgium be www markbelgium be MARK DEUTSCHLAND GmbH MAX PLANCK STRASSE 16 46446 EMMERICH AM RHEIN DEUTSCHLAND TELEFON 49 0 2822 97728 0 TELE...

Reviews: