MK4+ Hybrid Charge Controller User Manual
7
Step 3
Connect the battery to
“BATTERY” terminals with 10AWG or bigger
copper cables. The controller terminals can accept a maximum wire
diameter of 6mm (4 AWG). You must connect the battery to the
controller before connecting the wind turbine. We also recommend
that a 50A fuse or circuit breaker be placed on the positive (+) battery
cable within 12” of the battery.
(Note: While the controller is fuse
protected against a reverse-polarity connection, please do not
connect the cables with the polarity reversed.)
Step 4
Connect the three (3) wind turbine output wires to the
“WIND INPUT”
terminals only when the wind turbine is fully stopped and tied off to
prevent it from spinning.
Step 5
Connect any solar panels to the positive wire to (+)
“SOLAR INPUT”
terminal, negative wire to (-)
“SOLAR INPUT” terminal.
Step 6
User can set relevant parameters and adjust load output control
modes thru the LCD and the controller buttons.
Step 7
Check whether all the connections are correct and firmly tightened.