5
Electrical Wiring
1. Provide DC 12 Volt input power for 23050A / 23051A (Provide DC24 Volt input power for / A)
2. Protect input power positive (+) terminal with 10 A fuse or circuit breaker.
3. Use 12-gauge power cable for wiring distance not more than 30 ft (9 m), and use 10-gauge power
cable for longer wiring distance.
4. According to your control device, see below and the diagram:
(a) If handheld remote control, no additional wiring needed.
(b) If flush mounted remote control, provide input power to the mounted remote control. Protect
input power positive (+) terminal with 1 A fuse or circuit breaker.
!
Use correct product for your power source (DC12 or 24 Volt). Wrong voltage will damage product
and may cause safety hazard.
( b ) ( c )