background image

ENGLISH - 14

 

 

 
7.  HEAT  AND  TEMPERATURE:  Place  the  equipment 
far away from heat sources such as radiators, heat logs, 
stoves  or  other  electronic  equipment  (including 
amplifiers) that produce heat. 
 
8.  VENTILATION:  The  rack,  shelf  or  special  furniture 
where  you  place  the  equipment  must  have  ventilation 
slots or openings in order to protect the equipment from 
overheating. 
 
Place the equipment with at least 6 inches (16 cm) free 
space from the top and with a space behind it that allows 
a free flow of air. 
 
9.  GROUNDING  OR  POLARIZATION:  As  a  safety 
feature, the unit is equipped with a polarized alternating 
current  line  plug,  which  has  one  blade  wider  than  the 
other. This plug can be inserted in the electric outlet only 
one way. 
 
If you cannot insert the plug completely into the outlet, 
try inverting the plug. 
 
If the plug still does not fit correctly, contact a licensed 
electrician to update your obsolete outlet. Do not remove 
or damage the safety end of the polarized plug. 
 
10.  POWER  SOURCES:  Use  the  equipment  only  with 
outlets that have the power supply indicated in the label 
of the equipment. If you are not sure about the type of 
power  supplied  in  your  home,  contact  your  local 
electricity supplier. 
 
11.  POWER CORD PROTECTION: Fix the power cords 
in such a way that there is no risk of them being crushed, 
caught  or  squeezed  by  other  equipment  or  furniture. 
Particularly pay attention to the ends of the cords, both 
the end that goes into the outlet and the end that directly 
comes from the equipment. 
 
12.  LIGHTNING: For best protection during an electric 
storm or when the equipment is inactive for long periods 
of  time,  unplug  the  equipment  from  the  outlet  and 
disconnect the antenna or cable decoder. This will help 
protect  the  equipment  from  lightning  and  electrical 
surges. 
 
13.  ELECTRIC LINES: Do not place an external antenna 
system  near  the  aerial  electric  lines  or  other  electric 
power  circuits.  When  installing  an  external  antenna 
system,  you  must  be  very  careful  not  to  touch  the 
electric lines or circuits since contact with them may be 
lethal. 

 
14.  OVERLOAD:  Do  not  overload  the  wall  outlets, 
extension cords or power strips, since this increases fire 
and electrical shock hazards. 
 
15.  SAFETY VERIFICATION: After any service or repair 
to the equipment, ask the service technician to perform 
safety controls to make sure the equipment is in proper 
working condition. 
 
16.  IMPORTANT SAFETY NOTES: 
 
CAUTION: 
 
Any  modification  not  expressly  approved  by  Margules 
will make the warranty of the equipment void and may 
result in hazard for the user. 
 

 

Before  connecting  a  new  product  such  as  the 

ACRH-3 to your audio

 

or home theater system, turn off 

all other equipment (preferably by unplugging them from 
the AC power source). 
 
Many  audio  components  have  automatic  start  circuits 
that may activate during an installation; this could cause 
damage to the electronic components and/or speakers. 
This kind of damage is not covered by the warranty of 
this  product  and  as  such  Margules  specifically  is 
released of liability for said damages. 
 

 

The  detachable  power  cord  supplied  with  your 

equipment  was  specifically  designed  to  be  used  with 
this product; however, you may use other better-quality 
power cords in order to take the utmost advantage of the 
capabilities of this equipment. 
 
Ask your Margules distributor for advice on power cords 
that may be used with your system. 
 

 

For your protection, the product is equipped with an 

AC fuse (6A-SB) located on the back of the chassis. This 
fuse  may  be  replaced  by  the  user.  In  case  the  fuse  is 
replaced and the equipment does not turn on, contact an 
authorized service representative. The spare fuse must 
be always the one specified by the manufacturer. 
 

 

The electric wiring that runs inside the walls must 

have  the  proper  UL  certification  (Underwriters 
Laboratories)  to  indicate  satisfactory  compliance  with 
all requirements set forth by the regulations in force, and 
belong  to  the  list  authorized  by  the  UL,  CSA  or  other 
regulation required by the UL, CSA, NEC or your local 
construction code. Questions on electric wiring must be 
submitted to a certified installer, licensed electrician or 
low voltage contractor. 

Summary of Contents for ACRH-3

Page 1: ...GRATED AMPLIFIER Manual del Usuario Owner s Manual Dise ado y fabricado por Margules Designed and manufactured by Margules Morelia 38 4 Colonia Roma Morelia 38 4 Colonia Roma Ciudad de M xico C P 0670...

Page 2: ...I N 9 CONEXIONES Y OPERACI N 9 RECOMENDACIONES 10 SOLUCI N DE PROBLEMAS 10 NOTAS DE LA INSTALACI N 12 ENGLISH TABLE OF CONTENTS INTRODUCTION 13 SAFETY INSTRUCTIONS 13 CHARACTERISTICS 15 TECHNICAL SPEC...

Page 3: ...icio a este componente 1 MANUAL DEL PROPIETARIO Antes de encender el equipo lea y siga con atenci n todas las instrucciones de seguridad y funcionamiento Mantenga estas instrucciones para futuras refe...

Page 4: ...xterior deber tener mucho cuidado para evitar tocar las l neas el ctricas o circuitos ya que el contacto con ellos podr a ser fatal 14 SOBRECARGA No sobrecargue las tomas de corriente de pared cables...

Page 5: ...e la antena o el sistema de cable est n conectados a tierra para proporcionar protecci n contra cargas est ticas y aumentos de la tensi n El art culo 810 del C digo El ctrico Nacional ANSI NFPA 70 en...

Page 6: ...ise o de la etapa de preamplificaci n permite tener una salida preamplificada adicional PRE OUT 2 la cual puede ser usada para la conexi n de un subwoofer activo o si lo desea a otro amplificador Sali...

Page 7: ...ido en entradas auxiliares m ximo 0 22 mV Voltaje de Alimentaci n 120 VCA Consumo el ctrico sin se al Consumo el ctrico m ximo 40 watts 500 watts Medidas Alto 9 5 cm Ancho 43 cm Profundidad 38 cm Peso...

Page 8: ...bulbos Controlador del Volumen Selector de Fuente de Entrada Bot n de Encendido Apagado Monitor de Fuente de Entrada Salida para Bocinas Fusibles de Salida 3A Entrada de Amplificador Salidas de Preamp...

Page 9: ...n de cobre chapeado con oro para evitar la corrosi n y mejorar la conductividad por lo que debe de evitar forzarlas Los conectores o terminales de los altavoces pueden usarse con el cable de los altav...

Page 10: ...la reproducci n de la m sica En virtud de que la etapa de preamplificaci n usa bulbos para su funcionamiento evite conectar equipos con una carga de baja impedancia menos de 100 K La calidad as como e...

Page 11: ...s bases Un bulbo puede estar da ado Para identificar el bulbo defectuoso vea que los LED se encuentren encendidos En caso de que la luz LED no se encienda deber sustituir los bulbos de preamplificaci...

Page 12: ...ESPA OL 12 NOTAS DE LA INSTALACI N...

Page 13: ...quipment carefully read and follow all safety and operation instructions Keep this User Manual for future reference 2 ACCESSORIES AND SPARE PARTS Only use accessories recommended by Margules The use o...

Page 14: ...t to touch the electric lines or circuits since contact with them may be lethal 14 OVERLOAD Do not overload the wall outlets extension cords or power strips since this increases fire and electrical sh...

Page 15: ...antenna or cable system is connected to the equipment make sure the antenna or cable system is grounded to provide protection against static charges and surges Article 810 of the National Electrical...

Page 16: ...ditional output PRE OUT 2 which may be used for the connection of an active subwoofer or if so desired another amplifier Line Level Output Direct Output The ACRH 3 has a line level output controlled b...

Page 17: ...onic Distortion THD 0 02 Line input noise max 0 22 mV Supply voltage 120 VAC Electrical consumption no signal Maximum electrical consumption 40 watts 500 watts Dimensions Height 9 5 cm Width 43 cm Dep...

Page 18: ...ver Vacuum Tube Monitor Volume Control Input Selector On Off Switch Input Source Monitor Speaker Outputs Output fuses 3A Amplifier Input Preamplifier Outputs Line Level Inputs Phono Input Line Level S...

Page 19: ...s to prevent corrosion and improve conductivity so you should avoid forcing them The speakers connectors or binding posts may be used with bare wire banana plugs or spade connectors We recommend the u...

Page 20: ...s than 100 K The quality as well as the DC offset in the AC powerline are important to avoid any mechanical noise induced by the transformers Placing the amplifier on vibration dampening or isolation...

Page 21: ...be check that the LED indicator are lit If the LED indicator is not lit the tubes must be replaced 6 A humming sound is heard in both channels regardless of the position of the volume control The nois...

Page 22: ...ENGLISH 22 INSTALLATION NOTES...

Reviews: