background image

ENGLISH - 13

 

 

INTRODUCTION 

 
Congratulations. As the owner of an ACRH-3 integrated 
amplifier,  you  have  acquired  a  product  for  musical 
reproduction that incorporates cutting-edge technology 
developed from the knowledge gained by Margules over 
more than 30 years of research. 
 
This  one-of-a-kind  high-end  integrated  amplifier  was 
handcrafted  with  materials  and  components  of  the 
highest  quality,  observing  the  strictest  production 
processes and looking after the smallest detail. 
 
Thanks to its design philosophy, the ACRH-3 integrated 
amplifier merges innovation with functionality, offering 
uncompromised value and quality as well as versatility 
and convenience. All this to attain a single objective: the 
achievement of a dynamic and realistic sound, with low 
distortion  and  a  harmonic  reproduction  that  flows 
naturally. 
 
In the same way, this integrated amplifier will allow you 
to enjoy a captivating, engaging and natural sound since 
its conceptualization and development are built on the 
implementation  of  our  Neuro-Acoustic  Alignment 
technology (ANA

â

) based on the way the human brain 

perceives  sound,  prioritizing  harmonic  structure  over 
fundamental tone. 
 
In Margules Audio, we thank you for the trust you have 
granted us by acquiring our product, which will ensure 
years of pleasure and service. 
 

 

The ACRH-3 Integrated Amplifier offers the smoothness and 

warmth of the tubes together with excellent precision and 

potency in the amplification, creating a musical experience 

with Margules’ distinctive tonal richness. 

 

 

SAFETY INSTRUCTIONS 

 
WARNING:  To  avoid  electrical  shock  hazard,  do  not 
remove  the  amplifier’s  cover.  There  are  no  user-
serviceable parts inside so, in case of malfunction, we 
recommend only qualified personnel should service this 
component. 
 

 

 
1.  USER MANUAL: Before turning on the equipment, 
carefully  read  and  follow  all  safety  and  operation 
instructions. Keep this User Manual for future reference. 
 
2.  ACCESSORIES  AND  SPARE  PARTS:  Only  use 
accessories  recommended  by  Margules.  The  use  of 
accessories different to those recommended may cause 
damage  to  or  malfunction  of  the  equipment,  or  even 
create  hazards  while  operating.  If  spare  parts  are 
needed,  make  sure  the  service  technician  uses  spare 
parts specified by Margules. The use of non-authorized 
spare  parts  may  create  fire,  electrical  shock  or  other 
hazards.  In  order  to  maintain  the  warranty  of  the 
equipment, manipulation by personnel not authorized by 
Margules must be avoided. 
 
3.  PLACEMENT:  Do  not  place  this  equipment  on 
unstable  surfaces,  brackets,  tripods  or  tables.  The 
product could fall, causing personal injury or damage to 
the  equipment.  Always  place  the  equipment  according 
to  the  instructions  of  the  manufacturer  and  with  the 
recommended mounting accessories. 
 
Do not place the equipment near flammable materials or 
on surfaces that prevent heat dissipation such as beds, 
couches, carpets or racks without proper ventilation. 
 
4.  WATER  AND  HUMIDITY:  Do  not  operate  the 
equipment close to water (for instance, next to a pool, 
bathtub or sink) or in a humid environment (such as a 
basement), and do not expose it to the outdoors or rain. 
 
5.  MOUNTING ON WALLS OR CEILINGS: Only mount 
the  equipment  on  a  wall  or  ceiling  in  the  way 
recommended  by  the  manufacturer.  Call  the  service 
number  in  case  of  doubt  regarding  the  safe  way  to 
mount the equipment. 
 
6.  INSERTION OF OBJECTS AND ACCIDENTAL SPILL: 
Do  not  insert  any  objects  through  the  openings  of  the 
unit  since  they  could  touch  dangerous  voltage  points, 
creating the possibility of fire or electrical shock hazard. 
Avoid  spilling  liquids  onto  the  unit.  If  a  liquid  is 
accidentally spilled onto or if any metallic object (such 
as paper clips, coins or staples) is inserted into the unit, 
unplug  it  immediately  from  the  power  source  and 
contact Margules to receive instructions.

Summary of Contents for ACRH-3

Page 1: ...GRATED AMPLIFIER Manual del Usuario Owner s Manual Dise ado y fabricado por Margules Designed and manufactured by Margules Morelia 38 4 Colonia Roma Morelia 38 4 Colonia Roma Ciudad de M xico C P 0670...

Page 2: ...I N 9 CONEXIONES Y OPERACI N 9 RECOMENDACIONES 10 SOLUCI N DE PROBLEMAS 10 NOTAS DE LA INSTALACI N 12 ENGLISH TABLE OF CONTENTS INTRODUCTION 13 SAFETY INSTRUCTIONS 13 CHARACTERISTICS 15 TECHNICAL SPEC...

Page 3: ...icio a este componente 1 MANUAL DEL PROPIETARIO Antes de encender el equipo lea y siga con atenci n todas las instrucciones de seguridad y funcionamiento Mantenga estas instrucciones para futuras refe...

Page 4: ...xterior deber tener mucho cuidado para evitar tocar las l neas el ctricas o circuitos ya que el contacto con ellos podr a ser fatal 14 SOBRECARGA No sobrecargue las tomas de corriente de pared cables...

Page 5: ...e la antena o el sistema de cable est n conectados a tierra para proporcionar protecci n contra cargas est ticas y aumentos de la tensi n El art culo 810 del C digo El ctrico Nacional ANSI NFPA 70 en...

Page 6: ...ise o de la etapa de preamplificaci n permite tener una salida preamplificada adicional PRE OUT 2 la cual puede ser usada para la conexi n de un subwoofer activo o si lo desea a otro amplificador Sali...

Page 7: ...ido en entradas auxiliares m ximo 0 22 mV Voltaje de Alimentaci n 120 VCA Consumo el ctrico sin se al Consumo el ctrico m ximo 40 watts 500 watts Medidas Alto 9 5 cm Ancho 43 cm Profundidad 38 cm Peso...

Page 8: ...bulbos Controlador del Volumen Selector de Fuente de Entrada Bot n de Encendido Apagado Monitor de Fuente de Entrada Salida para Bocinas Fusibles de Salida 3A Entrada de Amplificador Salidas de Preamp...

Page 9: ...n de cobre chapeado con oro para evitar la corrosi n y mejorar la conductividad por lo que debe de evitar forzarlas Los conectores o terminales de los altavoces pueden usarse con el cable de los altav...

Page 10: ...la reproducci n de la m sica En virtud de que la etapa de preamplificaci n usa bulbos para su funcionamiento evite conectar equipos con una carga de baja impedancia menos de 100 K La calidad as como e...

Page 11: ...s bases Un bulbo puede estar da ado Para identificar el bulbo defectuoso vea que los LED se encuentren encendidos En caso de que la luz LED no se encienda deber sustituir los bulbos de preamplificaci...

Page 12: ...ESPA OL 12 NOTAS DE LA INSTALACI N...

Page 13: ...quipment carefully read and follow all safety and operation instructions Keep this User Manual for future reference 2 ACCESSORIES AND SPARE PARTS Only use accessories recommended by Margules The use o...

Page 14: ...t to touch the electric lines or circuits since contact with them may be lethal 14 OVERLOAD Do not overload the wall outlets extension cords or power strips since this increases fire and electrical sh...

Page 15: ...antenna or cable system is connected to the equipment make sure the antenna or cable system is grounded to provide protection against static charges and surges Article 810 of the National Electrical...

Page 16: ...ditional output PRE OUT 2 which may be used for the connection of an active subwoofer or if so desired another amplifier Line Level Output Direct Output The ACRH 3 has a line level output controlled b...

Page 17: ...onic Distortion THD 0 02 Line input noise max 0 22 mV Supply voltage 120 VAC Electrical consumption no signal Maximum electrical consumption 40 watts 500 watts Dimensions Height 9 5 cm Width 43 cm Dep...

Page 18: ...ver Vacuum Tube Monitor Volume Control Input Selector On Off Switch Input Source Monitor Speaker Outputs Output fuses 3A Amplifier Input Preamplifier Outputs Line Level Inputs Phono Input Line Level S...

Page 19: ...s to prevent corrosion and improve conductivity so you should avoid forcing them The speakers connectors or binding posts may be used with bare wire banana plugs or spade connectors We recommend the u...

Page 20: ...s than 100 K The quality as well as the DC offset in the AC powerline are important to avoid any mechanical noise induced by the transformers Placing the amplifier on vibration dampening or isolation...

Page 21: ...be check that the LED indicator are lit If the LED indicator is not lit the tubes must be replaced 6 A humming sound is heard in both channels regardless of the position of the volume control The nois...

Page 22: ...ENGLISH 22 INSTALLATION NOTES...

Reviews: