Set up the moisture indicator and the

leak detector alarm.

Diagram 2

The indicator will blink twice in green (diagram 1)

Then keep blinking in yellow (diagram 2)

Diagram 1

Press the red on/off button for one
second to turn on the leak detector

Press the battery gently
till it touches the bottom.

Take out the insulation

film of the battery.

Summary of Contents for MX-A7IV

Page 1: ...NY A7IV MIRRORLESS CAMERA Users Manual Please read this users manual carefully before starting to use the product and use the product properly based on the thorough understanding of this users manual...

Page 2: ...n housing body in humid or sandy environment to avoid damage of electronic circuit or leakage caused by small objects 9 Before opening the housing body or uninstalling the extension ring and port when...

Page 3: ...4 After ensuring the O Ring is in good condition use fingers to apply a thin layer of lubricant on the O Ring Be aware that too much lubricant may make dust sand hair or other small objects easy to st...

Page 4: ...Ball Mount 16 Handle 17 Zoom Dial 18 Lens Release Front Back Side View 8 7 Fiber Connector 8 OK 9 Arrow Button 10 Security Lock 11 DISP 12 IOS 1 1 C3 2 MENU 3 Fn 4 Alarm Light 5 Continuous shooting 6...

Page 5: ...5 Part Names and Functions Up Down View Up Down Side View 26 25 21 19 25 Sacrificial Anode 26 1 20 UNC Screw Hole 19 MODE 20 Fiber Connector 21 ON OFF 22 C2 23 EV 24 Rear Dial 20 24 23 22...

Page 6: ...6 Part Names and Functions Left Right Side View 32 33 31 30 29 28 27 32 RED 33 Rear Dial 34 LOCKOPEN 27 C1 28 Replay 29 AF ON 30 AEL 31 Shutter 34...

Page 7: ...7 Install Camera...

Page 8: ...the mounting base by pushing the handle to the left the handle to the left to secure it Align the baseplate below the camera to the slot on the mounting base and push the camera Push the handle on the...

Page 9: ...9 Remove Camera Push the handle back to the left to lock it Pull the camera out of the mounting base Push the handle to the right to release the camera from the mounting base...

Page 10: ...nside and out side the housing Separate back cover from front cover of the housing with both hands Push the buttons of security locks on both sides simultaneously Push the buttons of security locks on...

Page 11: ...es of front and back cover Push both knobs of the security locks downwards to the end Push both knobs of the security locks downwards to the end Push the security locks on both sides inwards till a cl...

Page 12: ...2 The indicator will blink twice in green diagram 1 Then keep blinking in yellow diagram 2 Diagram 1 Press the red on off button for one second to turn on the leak detector Press the battery gently ti...

Page 13: ...13 Mounting Ball Installation Diagram Handle Ball Mount M5 Screw M5 Spring Washer M5 Washer Lift Ring...

Page 14: ...from the housing 2 Clean the O Ring and the slot on the housing with a soft cloth make sure there is no salt or other foreign objects remaining Gently put lubricant on the O Ring Put the O Ring back i...

Page 15: ...sealing groove Set the safety lock of the extension ring in bulge state As shown in figure 01 02 03 Align the dot sign on the extension ring to the bar sign on the dome port then press the extension...

Page 16: ...dot sign on the extension ring is aligned with the dot sign on the dome port Turn the dome port to verify that the safety lock is locked As shown in Figure 2 2 Figure 2 05 Press the button on the exte...

Page 17: ...ing with the dot sign of the housing then press the extension ring onto the housing till they are fully attached As shown in Figure 3 Figure 4 Figure 3 07 Rotate the extension ring clockwise until the...

Page 18: ...18 08Push the extension ring lock of the housing inwards till it s fully locked...

Page 19: ...extension ring aligns to the dot sign of the housing As shown in Figure 1 02 Figure 1 1 03 Separate the extension ring with the dome port from the housing in the direction shown As shown in Figure 2 F...

Page 20: ...5 Figure 3 2 Rotate the extension ring clockwise until the dot sign on the extension ring reached the bar sign of the dome port As shown in Figure 3 04Press down the safety lock inside the extension r...

Page 21: ...21 Remove the dome port from the extension ring in the direction shown As shown in Figure 4 06 Figure 4...

Page 22: ...ning it counter clockwise Put the cap back onto the vacuum valve by turning it clockwise till it s tight Put the nozzle of the pump on the vacuum valve push and pull the handle of pump to extract air...

Page 23: ...23 Release Vacuum Valve Remove the cap on the vacuum valve by turning it counter clock wise Pull the red knob on the vacuum valve upwards Till the vacuum indicator light turns red...

Page 24: ...ner and outer side of the gear ring Put one or two small rubber bars into each slot 2 Adjust it till the contact between the lens and ring is neither too tight nor too loose Then push the aluminum out...

Page 25: ...25 Install Lens So the zoom dial and the gear parts inside the housing move sideway to leave enough space for lens to move through the front port of the housing Push the wedge on the zoom dial forward...

Page 26: ...26 Remove Lens Push the wedge on the zoom dial back to its original position Press the lens release button and turn the lens to release it from the camera Push the wedge on the zoom dial forward...

Page 27: ...the glass on the dome or macro port 4 After each dive clean the O rings and check if there are damages on the O rings 5 Use sturdy and shock proof case to carry the housing and its accessories don t p...

Page 28: ...sage of non Marelux recommended accessories parts components from other makers or suppliers such as Flash Trigger Cable Dome Port Extension Ring Convert or and etc Damage caused by misuse or mistreatm...