background image

7

Mareli Systems

Additional instructions:

1.  Remove the ash and slag from the boiler once a week or according to the volume of ashtray.

2.  Check boiler flues periodically and clean them if there is congestion.

3.  Check the burner adjustment once a year using a gas analyser.

4.  Clean ash at the pellet hopper bottom once a year.

5.  Clean boiler chimney once every two years.

6.  If there is law draught in the chimney, install additional chimney suction fan. Its control is planned and 

integrated in the control unit of the burner.

The maintenance timetable is recommended, cleaning must be made whenever necessary. 
The need of cleaning varies individually, since the choice of pellets, the system itself, and the settings of the 

burner affect the frequency of cleaning. Unforeseen risks upon cleaning and maintenance. 

Hand burn hazard: 

Possible reason – high temperature in the burning chamber. This risk exists in case of 

unburned fuel pellet, as well as not cooled burner when cleaning by the user! 

It may occur upon cleaning and maintenance of the burner. The use of special protective equipment (gloves) 

is recommended! 

Electrical shock hazard:

 The maintenance of the burner during operation as well as under voltage is pro-

hibited! If a short circuit or possible damage occurs, an authorised technician should be called. Touching the 

conducting parts is prohibited! 

Dust in eye hazard:

 May occur during work both upon cleaning and maintenance. The use of special protec-

tive equipment (safety goggles, tightly fitted) is recommended! 

 
CAUTION: Periodic cleaning, as well as supervision of the burner will prevent any incidents caused by faulty 

pellet fuel, incorrect slopes of burner and of screw conveyor, as well as incorrect combustion settings. Read this 

manual before installing and working with the burner. The manufacturer bears no responsibility!
A burner with properly adjusted settings operates well and cost-efficiently. If there are problems, please, con-

tact the supplier for the removal of any defects or for setting up the burner.

POSSIBLE FAULTS AND TROUBLESHOOTING:

 

The verification shall be carried out only by a qualified electrical technician or an authorized by Mareli Systems 

service centre.
The unit does not work:

• 

Check the hopper for sufficient quantity of pellets.

• 

Check operation of the heater.

• 

Check operation of the screw conveyor (whether it feeds pellets). Check the flexible connection. The 

facility does not start: (display is not illuminated).

• 

Check fuses on the circuit board.

• 

Check the power source for loose connections. 

ATTENTION! CUT OFF THE POWER SUPPLY.

Ignition failure:

• 

The initial dose of pellets is insufficient (increase parameter 02)

Faulty heater - check it with a multimeter

• 

High fan speed (decrease parameter 04) 

Fuel feeding is OK, but the ignition fails:

• 

Check the igniting heater with a multimeter;

• 

Check the voltage supplied to the igniting heater with a multimeter;

• 

Upon interruption of the facility’s operation (poor combustion, etc.) check the condition of the flue and 

clean any debris and soot caused by the condensation.

Summary of Contents for SMB 50

Page 1: ...SMB 50 Pellet burner Assembly and exploitation manual Mareli Systems...

Page 2: ...y an adult who is familiar with the operating conditions Introduction of inflammable liquids in room with a working burner is strictly prohibited Children should not be left unattended in the room whe...

Page 3: ...lied to the flexible tube The flexible tube is made of special heat resistant material which in the case of combustion does not emit toxic substances and connects the auger and pellet burner End view...

Page 4: ...urely attach a pellet burner to the door through M8 screws which are screwed where the thread is made on the door itself which holds the burner to the door Explanation It must be checked whether seali...

Page 5: ...or about 3 hours for the chimney to be warmed up and measure the draught Install addition al chimney fan controlled by the control unit of the burner if necessary The heat exchange surface is made of...

Page 6: ...omical and efficient operation of the boiler burner system in the installation Why is regular maintenance important Heating systems should be maintained on a regular basis for the following reasons To...

Page 7: ...aintenance The use of special protec tive equipment safety goggles tightly fitted is recommended CAUTION Periodic cleaning as well as supervision of the burner will prevent any incidents caused by fau...

Page 8: ...from the burner and collect the pellets passed from the conveyor into a bag for 10 min Weigh the pellets passed and multiply by the factor 0 03 The calculated value is the power in KW h Example If th...

Page 9: ...ner settings to use exhaust gas analyser IMPORTANT Default values of the parameters should not be taken for granted The settings must be adjusted individually according to REQUIRED POWER TILT OF THE S...

Page 10: ...user you may only make repairs which involve just a simple replacement of the grate In case of first commissioning of the boiler condensation of water vapour on the heating surfaces of the heat excha...

Page 11: ...stat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to problems of adjustment of the number of rev...

Page 12: ...ond case the user selects the desired power On the left side of the display are signalled the combustion modality A automatic combustion M manual combustion and the working power of the system Recipe...

Page 13: ...day at the desired time Ex 6 30 The system turns on at 20 30 on Tuesday and turns off at 6 30 on Wednesday Weekly The programs are the same for all days of the week Week end Choose between Monday Fri...

Page 14: ...14 Mareli Systems WIRING DIAGRAM...

Page 15: ...15 Mareli Systems...

Page 16: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics Mareli Systems MareliSystems I...

Reviews: