10

Mareli Systems

Description

 

Code 

Sond

Hi

Clean

Port

Ignition 

block

Cleaning on

Link Error

Anomaly of the probes checking, during Check Up phase.
Room temperature greater than 99 °C.
This message notifies that the planned hours of functioning are reached.
Door Open.

The message appears if the system is turned off during Ignition (after Preload) not manually: 

the system will stop only when it goes in Run Mode.

Periodical Cleaning in progress.
No communication between motherboard and keyboard

MESSAGES

Exhaust T. [°C]

  - Exhaust temperature;

Room T. [°C]

  - Local room temperature; it is visible only if;

Buffer T. [°C]

 - Buffer Temperature;

Pressure [mbar]

 - Water pressure;

Air Flux

 - Air flow;

Fan Speed [rpm]

 - Exhaust fan speed;

Auger [s]

 - Auger work time;

Recipe [nr]

 - Combustion recipe set;

Product Code: 510

 - Product code;

VISUALIZATIONS

USER MENU 1

Combustion Management

Power - 

In this menu is possible to modify the combustion power of the system. It can be set in automatic or 

manual modality . In the first case the system chooses the combustion power. In the second case the user selects 

the desired power. On the left side of the display are signalled the combustion modality (A=automatic combustion, 

M=manual combustion) and the working power of the system.

Recipe 

- Menu to select the combustion recipe. The maximum value is the number of recipes visible to the user. 

Auger Calibration - 

It allows to modify the value set in firm of Auger’s speed or On times. The values are in the 

range – 7 ÷ 7. The firm’s value is 0.

Fan Calibration - 

It allows to modify the value set in firm of Combustion Fan’s speed. The values are in the range 

– 7 ÷ 7. The firm’s value is 0.

Heating Management
Boiler thermostat 

- Menu to change the value of the boiler thermostat .

Buffer thermostat - 

Menu to change the value of the Buffer Thermostat.

Room Thermostat - 

This Menu allows to modify the Local Room Thermostat’s value. It is visible only if the ambient 

probe is select.

Summer-Winter -

 Menu that allows the selection Summer-Winter.

Manual Load

The procedure activates the pellet manual loading with activation in continue modality of the Auger engine. The 

loading is stopped automatically after 600 seconds. The system must be OFF for the function can be activated.

Cleaning Reset

 

Menu to reset the ‘System Maintenance 2’ function.

Summary of Contents for CB 35

Page 1: ...Combined Boiler MARELI CB 35 Assembly and exploitation manual Mareli Systems...

Page 2: ...f this series are designed to uti lize solid fuel wood coals It has a welded steel con struction The resulting heat is absorbed by the heat ex change surface of the boiler body and transmitted the hea...

Page 3: ...is to be mounted The funnel with an outer diameter of F145 is situated in the upper rear part of the boiler and leads off the smoke gasses through the chimney The steel heat exchanger is isolated wit...

Page 4: ...onnecting the safety heat exchanger Filling the heating installation and density check 4 Instructions for connecting the air supply and exhaust gases Making the connection with the chimney Keep in min...

Page 5: ...joints to the water tank of which can not be closed are mounted Close the connection between the enlarging pot and the system by closing the valve Open the mixing and the stopping valves from the wate...

Page 6: ...low and this results in better gas efficiency For this purpose pull the valve lever at the rear side of the heating boiler to a vertical po sition after 10 15 minutes Info An excessive air supply may...

Page 7: ...may freeze due to low temperatures If possible leave the heating installation constantly running Protect the heating installation from freezing by eventually draining the heating installation on the...

Page 8: ...ressure of at least 1 bar Check the working pressure of the heating installation If the manometer pointer is under the red point er then the working pressure is too low Water must be added Instruction...

Page 9: ...tat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to problems of adjustment of the number of revo...

Page 10: ...ond case the user selects the desired power On the left side of the display are signalled the combustion modality A automatic combustion M manual combustion and the working power of the system Recipe...

Page 11: ...day at the desired time Ex 6 30 The system turns on at 20 30 on Tuesday and turns off at 6 30 on Wednesday Weekly The programs are the same for all days of the week Week end Choose between Monday Fri...

Page 12: ...12 Mareli Systems WIRING DIAGRAM SMB 50...

Page 13: ...13 Mareli Systems WIRING DIAGRAM PB 40 52...

Page 14: ...14 Mareli Systems...

Page 15: ...15 Mareli Systems...

Page 16: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics Mareli Systems MareliSystems I...

Reviews: