background image

2

Mareli Systems

• 

“Mareli Systems” expresses its gratitude towards the clients who purchased the manufactured products.

• 

“Mareli Systems” provides the present manual as an aid to the team, which will install, adjust and main-

tain the device, as well as to the client which will exploit it.

• 

“Mareli Systems” requires that the technicians who will carry out the above mentioned procedures have 

passed a training course on the activities, associated with this product.

ATTENTION! For Your safety, it’s necessary to read carefully this manual as well as the exploitation and instal-

lation manual of the automated pellet burner before attempting any installation, adjustment and exploitation 

activities. Also read the installation and exploitation manual of the pellet bunker if the device is provided with 

one.  The non-fulfillment of prescriptions and violation of active regulations and directives may lead to damage 

and unexpected consequences for which “Mareli Systems” accepts no responsibility.

1. Description and advantages of the Combined Boiler “CB 35 Kw”

The Combined Boiler of this series are designed to uti-

lize solid fuel (wood, coals). It has a welded steel con-

struction. The resulting heat is absorbed by the heat ex-

change surface of the boiler body and transmitted the 

heating system. These boilers used for heating in local 

heating systems, but also for heating domestic water.

Automated pellet burner is part of the system and can 

utilize the following types of fuel: Wood pellets size 6 

and 8 mm Class A;

The full set consists of: 

• 

Water heating boiler, representing a steel heat ex-

changer for warming up the heat conductor;  

• 

Automated pellet burner equipped with a control 

panel;

The system consists of:

• 

Water heating boiler (the boiler is equipped 

with two doors depending on the type of fuel 

that is going to be used);

The heating boiler consists of:

• 

Steel body;

• 

Thermal regulator; 

• 

Door for mounting a burner;

• 

Thermometer/manometer;

The desired temperature of the boiler water is ad-

justed with the regulator and is maintained at this 

maximal value.
The airflow is controlled by a valve (connected to 

the regulator).  At the back there is a compartment 

that contains the ash residue.
The thermometer/manometer indicates the temper-

ature in the heating boiler and the water pressure.

2. Description of the system: water heating boiler heat exchanger

Summary of Contents for CB 35

Page 1: ...Combined Boiler MARELI CB 35 Assembly and exploitation manual Mareli Systems...

Page 2: ...f this series are designed to uti lize solid fuel wood coals It has a welded steel con struction The resulting heat is absorbed by the heat ex change surface of the boiler body and transmitted the hea...

Page 3: ...is to be mounted The funnel with an outer diameter of F145 is situated in the upper rear part of the boiler and leads off the smoke gasses through the chimney The steel heat exchanger is isolated wit...

Page 4: ...onnecting the safety heat exchanger Filling the heating installation and density check 4 Instructions for connecting the air supply and exhaust gases Making the connection with the chimney Keep in min...

Page 5: ...joints to the water tank of which can not be closed are mounted Close the connection between the enlarging pot and the system by closing the valve Open the mixing and the stopping valves from the wate...

Page 6: ...low and this results in better gas efficiency For this purpose pull the valve lever at the rear side of the heating boiler to a vertical po sition after 10 15 minutes Info An excessive air supply may...

Page 7: ...may freeze due to low temperatures If possible leave the heating installation constantly running Protect the heating installation from freezing by eventually draining the heating installation on the...

Page 8: ...ressure of at least 1 bar Check the working pressure of the heating installation If the manometer pointer is under the red point er then the working pressure is too low Water must be added Instruction...

Page 9: ...tat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to problems of adjustment of the number of revo...

Page 10: ...ond case the user selects the desired power On the left side of the display are signalled the combustion modality A automatic combustion M manual combustion and the working power of the system Recipe...

Page 11: ...day at the desired time Ex 6 30 The system turns on at 20 30 on Tuesday and turns off at 6 30 on Wednesday Weekly The programs are the same for all days of the week Week end Choose between Monday Fri...

Page 12: ...12 Mareli Systems WIRING DIAGRAM SMB 50...

Page 13: ...13 Mareli Systems WIRING DIAGRAM PB 40 52...

Page 14: ...14 Mareli Systems...

Page 15: ...15 Mareli Systems...

Page 16: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics Mareli Systems MareliSystems I...