To ensure the correct directional flow of the fluid as indicated by the arrow on the top plate, it is 

necessary to connect the positive pole (+) of the battery supply to the red wire on the motor 

end-cap and the negative pole (-) to the black wire. Electrical connections must be made 

using  adequate  terminal  blocks  and  connectors  ensuring  a  tight  fitment  of  the  electrical 

cables. Bad wiring can cause power losses and/or overheating of the cabling itself.

Ø

Ø

Ø

Prior to making any tube/hose connections, check that the inlet ports have no end 

caps;

Do not position the pump at a excessive height with respect to the minimum level of 

the fluid to be transferred. Damage may occur if this height is exceeded as the pump 

may not draw fluid. Make sure that the outlet tube is empty and without chokes;

Avoid choking the inlet or outlet tubes so that efficiency is optimized. 

The use of an inlet filter is recommended especially with fluids containing impurities 

(mesh ASTM no. 35). 

Utilize tubes and connection pieces that are resistant to the fluid types handled and 

avoid any possible environmental dispersion.

Ø

 

Ø

In this case frequent cleaning and maintenance of the filter is 

advisable. The standard filter withstands a maximum positive pressure of 0.5 bar.

The electrical installation of the pump must include a protection fuse which is suitably rated 

as indicated on the motor label.

Always  mount  the  anti  vibration  rubber  fittings  supplied  with  the  pump  kit.  Their  usage 

ensures a consistent reduction in noise and vibration levels. Electrical cabling size should 

depend on the distance between pump and battery/power supply (see Tab.1 EN). The use of 

undersized  cabling  can  cause  overheating  of  the  electrical  wiring  and  subsequent  fire 

hazard. There will also be a voltage drop at the motor terminals with a consequent reduction 

in efficiency. The flow rate value indicated on the motor label is obtained with internal tube 

diameter  indicated  on Tab.1  EN. Tubes  with  inferior  diameters  will  cause  an  increase  in 

current with potential risk of  motor overheating. 

WARRANTY EXPIRES IF NO FUSE IS UTILIZED

WARNING:

 it is the responsibility of the installation technician to ensure a correctly 

designed circuit installation fitted according to regulations. Environmental risks must 

be taken into account with the installation.

Summary of Contents for 164 622 13-US

Page 1: ...30 07 19 Rev 00 S p A INSTRUCTIONS FOR USE SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING VARIOUS LIQUIDS 164 622 13 US UP6 E 24V...

Page 2: ......

Page 3: ...IVATION When starting the pump or when emptying the tank slightly open the small valve in order to let the air out and facilitate the priming As soon as the pump is operating close the small valve ELE...

Page 4: ...an five times from priming to no liquid blue led off the circuit turns everything off anyway to protect the motor and the gears from running without liquid The multicolored LED signals With solid yell...

Page 5: ...have to reboot the circuit or presstheReset buttononthecontrol panel if present Yellow and blue LED that blink together indicate that the power supply is providing the wrong voltage Please check to h...

Page 6: ...ds of applications for the pump however only exclusively with the allowed liquids mentioned Tab 1 EN CODE TYPE VOLT IP 67 Protection gpm 6 9 psi 50 8 lb 8 2 164 622 13 US UP6 E 24 WIRE SIZE AWG 14 Int...

Page 7: ...shipment Upon receiving the packaging should be inspected for damages and the pump stored in a dry area It is recommended that the use of the pump be according to normative safety standards and also a...

Page 8: ...oidany possibleenvironmental dispersion In this case frequent cleaning and maintenance of the filter is advisable The standardfilter withstands a maximumpositive pressure of0 5 bar The electrical inst...

Page 9: ...umphas run dry for too long a period Long periods of inactivity In this case it is advisable to add liquid directly into the chamber beforestart up Air leak at the suction pipe due to the following re...

Page 10: ...pose of this product by means of the specific refuse collection structures indicated by the government orthe local governing authorities The user is invited to effect a proper waste separation in orde...

Page 11: ...S p A EXPLODED VIEW 11...

Page 12: ...S p A DIMENSIONS mm pollici inches 12...

Page 13: ...S p A DIAGRAMS FLOW RATE DIAGRAM AMPERE DRAW DIAGRAM 13 0 2 5 5 7 5 10 0 0 14 5 29 0 43 5 58 0 psi gpm 0 2 5 5 7 5 10 0 0 14 5 29 0 43 5 58 0 psi A...

Page 14: ...ty Requirements for household appliances electric tools and similar apparatus Part 2 Immunity This declaration is valid for all products which are produced in accordance with the technical documentati...

Page 15: ......

Page 16: ...f MARCO S p A reproduction prohibited All rights reserved For further information visit our web site www marco it Marco S p A Via Mameli 10 25014 Castenedolo Brescia Italy tel 39 030 2134 1 Fax 39 030...

Reviews: