TRANSPORTATION AND HANDLING

INSTALLATION

                PRELIMINARY CHECKS

                                       POSITIONING 

AMBIENT CONDITIONS

TEMPERATURE:

RELATIVE HUMIDITY:

min.-10°C 14°F-max.60°C 140°F

max. 90 %

OPERATING CYCLE

Under  conditions  of  high  operating  pressures  the  pump  can  be  subjected  to  elevated 

stresses and overheating and therefore should not be used for prolonged periods under such 

conditions.

Due to limited weight  and dimensions the  pump does not require the use of  any  special 

handling  or  lifting  equipment. When  handling  manually,  normal  personal  protective  gear 

should be worn (safety shoes with toe piece, etc.). The pump is carefully packed prior to 

shipment. Upon receiving, the packaging should be inspected for damages and the pump 

stored in a dry area.

It is recommended that the use of the pump be according to normative safety standards 

and also as per the precautions listed below.

The pump can be mounted in any position. Fix the pump utilizing suitable diameter screws 

corresponding to the holes.

Check that there has been no damage to the pump during transportation or storage. Both 
inlet  and  outlet  ports  should  be  carefully  cleaned  removing  possible  dust  or  residual 
packaging  material.  Verify  that  the  available  electrical  power  supply  corresponds  to  the 
specification requirements.

WARNING:

 the above indicated temperature ranges are applicable to all components 

of the pump and these limits must be respected in order to avoid any possible damage 

or malfunctioning.

7

Summary of Contents for 164 622 13-US

Page 1: ...30 07 19 Rev 00 S p A INSTRUCTIONS FOR USE SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING VARIOUS LIQUIDS 164 622 13 US UP6 E 24V...

Page 2: ......

Page 3: ...IVATION When starting the pump or when emptying the tank slightly open the small valve in order to let the air out and facilitate the priming As soon as the pump is operating close the small valve ELE...

Page 4: ...an five times from priming to no liquid blue led off the circuit turns everything off anyway to protect the motor and the gears from running without liquid The multicolored LED signals With solid yell...

Page 5: ...have to reboot the circuit or presstheReset buttononthecontrol panel if present Yellow and blue LED that blink together indicate that the power supply is providing the wrong voltage Please check to h...

Page 6: ...ds of applications for the pump however only exclusively with the allowed liquids mentioned Tab 1 EN CODE TYPE VOLT IP 67 Protection gpm 6 9 psi 50 8 lb 8 2 164 622 13 US UP6 E 24 WIRE SIZE AWG 14 Int...

Page 7: ...shipment Upon receiving the packaging should be inspected for damages and the pump stored in a dry area It is recommended that the use of the pump be according to normative safety standards and also a...

Page 8: ...oidany possibleenvironmental dispersion In this case frequent cleaning and maintenance of the filter is advisable The standardfilter withstands a maximumpositive pressure of0 5 bar The electrical inst...

Page 9: ...umphas run dry for too long a period Long periods of inactivity In this case it is advisable to add liquid directly into the chamber beforestart up Air leak at the suction pipe due to the following re...

Page 10: ...pose of this product by means of the specific refuse collection structures indicated by the government orthe local governing authorities The user is invited to effect a proper waste separation in orde...

Page 11: ...S p A EXPLODED VIEW 11...

Page 12: ...S p A DIMENSIONS mm pollici inches 12...

Page 13: ...S p A DIAGRAMS FLOW RATE DIAGRAM AMPERE DRAW DIAGRAM 13 0 2 5 5 7 5 10 0 0 14 5 29 0 43 5 58 0 psi gpm 0 2 5 5 7 5 10 0 0 14 5 29 0 43 5 58 0 psi A...

Page 14: ...ty Requirements for household appliances electric tools and similar apparatus Part 2 Immunity This declaration is valid for all products which are produced in accordance with the technical documentati...

Page 15: ......

Page 16: ...f MARCO S p A reproduction prohibited All rights reserved For further information visit our web site www marco it Marco S p A Via Mameli 10 25014 Castenedolo Brescia Italy tel 39 030 2134 1 Fax 39 030...