Step 4 

– Place Into Service 

 

Place the SPuck on a flat surface.  If water comes in contact with either 
of the water sensors, the SPuck will send an alarm to the MarCELL.  
When transmitting the SPuck

’s LED will flash quickly.

 

 

Once a SPuck detects the presence of water and sends the alarm 
signal, it will be deactivated to preserve battery life.  When the water 
that caused the alarm is no longer present, the SPuck will 
automatically reset after 15 minutes.  You can also rearm the SPuck by 
making sure the sensors are dry and pressing and releasing the test 
button.  When the button blinks blue your SPuck is back in service and 
ready to detect water again.  

 

NOTE:  

The SPucks water detection circuit is designed to be very 

sensitive.  If the sensors remain wet after the test button press the 
SPuck will indicate this by flashing 1 short blue pulse every 5 seconds.  
If you see this, please dry the sensors more thoroughly or wait a few 
minutes for them to dry off.  When the sensor has reset the 1 pulse 
flash will stop. 

Changing the battery 

 

 

Turn the SPuck over  so the made in the USA label is facing towards 
you 

 

Slide the back cover up 

¼” – this will take a little force and you will 

hear a click 

 

Lift the back cover off 

 

Slide the CR2025 coin cell down and replace it with the new battery.  If 
this is done properly you will see the button flash 4 times. 

 

Replace the back cover 

Technical Specifications

 

Battery : CR2025 Coin Cell 

 

Radio : 915Mhz ISM band, 19.2k baud 

 

Size : 1.42

” (width) 1.92” (length) 0.40” (height) 