8. SERVICE PROCEDURE
TUNER
1. Requried Equipments
- AM Standard Signal Generator (AM SSG)
- Audio Generator
- Oscilloscope
- Distortion Meter
- AC Voltmeter
- DC Voltmeter
- FM Standard Signal Generator (FM SSG)
- Frequency Counter
- Stereo Modulator
Note : Disconnect external FM antenna prior to alignment.
2. Alignment
2-1. Alignment Test Points
MICRO-COMPUTER
To check the microcomputer firmware version, press 6.1 CH IN button and SLEEP button simultaneously while
power is on. The version number is shown on the main display of the unit.
Ex. V 020716 01
Step
Subject
Signal
generator
setting
Set
frequency
setting
Equipment
connection
Adjustment
point
Adjust for
1
Tunning
voltage
522kHz
522kHz
DC voltmeter
RF BLOCK
OSC coil
522 kHz : 1.0 ~ 1.3V
1611 kHz : 7.0 ~ 8.5V
2
IF Tracking
603kHz
603kHz
IF BLOCK
Coil
KSNT-111I
Maximize audio output
3
RF Tracking
603kHz
603kHz
AC voltmeter
oscilloscope
tape monitor
L/R
AC voltmeter
oscilloscope
tape monitor
L/R
AC voltmeter
oscilloscope
tape monitor
L/R
RF BLOCK
ANT coil
Maximize audio output
Repeat LOW, HIGH
frequency
4
Seek level
999kHz
999kHz
(/A/K/N)
(/A/K/N)
(/A/K/N)
(/A/K/N)
(/A/K/N)
(/A/K/N)
(/A/K/N)
(/A/K/N)
520kHz
(/U)
520kHz
(/U)
600kHz
(/U)
600kHz
(/U)
600kHz
(/U)
600kHz
(/U)
1000kHz
(/U)
1000kHz
(/U)
SVR 03
Tuned on point
Step
Subject
Signal
generator
setting
Set
frequency
setting
Equipment
connection
Adjustment
point
Adjust for
1
Tunning
voltage
152kHz
152kHz
DC voltmeter
RF BLOCK
OSC coil
522 kHz : 1.5 ~ 2.3V
1611 kHz : 6.0 ~ 7.5V
2
RF Tracking
162kHz
162kHz
AC voltmeter
oscilloscope
tape monitor
L/R
AC voltmeter
oscilloscope
tape monitor
L/R
RF BLOCK
ANT coil
Maximize audio output
Repeat LOW, HIGH
frequency
3
Seek level
207kHz
207kHz
Tuned on point
2-2. AM(MW) Alignment
Output of signal generator should not be greater than necessary to obtain an optimum output reading.
Signal generator modulation ................................................................. 30%
Signal frequency ................................................................................ 400Hz
Modulation frequency ........................................... 603, 999, 1404kHz (/A/K/N)
Modulation frequency ............................................ 600, 1000, 1400kHz (/U)
Switch ........................................................... press the BAND Button to AM
2-3. LW Alignment (/A/N)
Output of signal generator should not be greater than necessary to obtain an optimum output reading.
Signal generator modulation ................................................................. 30%
Signal frequency ................................................................................ 400Hz
Modulation frequency ....................................................... 162, 207, 252kHz
Switch ........................................................... press the BAND Button to LW
59
60
Summary of Contents for SR5300
Page 6: ...4 MEMO ...
Page 7: ...5 6 2 WIRING DIAGRAM ...
Page 8: ...7 8 3 BLOCK DIAGRAM ...
Page 9: ...9 10 4 SCHEMATIC DIAGRAM ...
Page 10: ...11 12 ...
Page 11: ...13 14 ...
Page 12: ...15 16 ...
Page 13: ...17 18 ...
Page 14: ...19 20 ...
Page 15: ...21 22 ...
Page 16: ...23 24 ...
Page 17: ...25 26 ...
Page 23: ...37 38 D701 703 IC712 IC710 IC703 D706 Q705 Q704 Q702AFL Q702 Q702AFR IC713 DSP ...
Page 25: ...41 INPUT 1 IC401 IC404 IC403 INPUT 2 D501 D502 ...
Page 27: ...43 IC808 IC806 IC805 IC804 IC802 IC803 IC807 S VIDEO MULTI CONTROL ...
Page 28: ...44 Q822 D870 D871 Q821 Q871 Q870 Q822A D873 D884 D872 VIDEO SPEAKER A ...