3. System u-com Update (IC11)
3.1. Items to Be Prepared
(1) Obtain "
Flash_loader_demonstrator_vX.X.X_Setup
" from the ST Microelectronics website.
(2) Personal Computer (Be installed "
Flash_Loader_Demonstrator_vX.X.X_Setup.exe
").
(3) RS-232C cable (9P (Male), Straight).
(4) 8U-210100S WRITING KIT (OLD JIG : SPK-581 WRITING KIT)。 7P FFC (Straight)
3.2. Connecting the WRITING KIT to This Unit
(1) Check that the power of this unit is off.
(2) Connect the RS-232C cable to the computer and WRITING KIT.
(3) Connect the update terminal of this unit to the WRITING KIT.
RESET
5V
3.3V
LOW
HIGH
CNVSS
EPM
CE
DSPBOOT
Computer
① Connect the RS-232C cable.
(Straight cable)
↑Top side is contacts of
flexible card cable.
Using the 7P FFC(Straight).
●
is 1PIN side.
→ This side is contacts of
flexible card cable.
●
is 1PIN side.
Align the switch in the direction of the arrow.