6
CAUTION IN SERVICING
Firmware update
•
When you replace the DIGITAL UNIT ASSY (8U-310051E), you need software updates.
Refer to "VERSION UPGRADE PROCEDURE OF FIRMWARE (26 - 36 page) .
Please update the following procedure.
1. First, Please update by DFW (33 - 36 page).
2. Next, Please update the latest
fi
rmware by DPMS (26 - 32 page).
Initializing AV Pre Tuner
AV Pre Tuner initialization should be performed when the
μ
com, peripheral parts of
μ
com, and Digital P.W.B. are
replaced.
1. Turn off the power using ON/STANDBY button.
2.
Press ON/STANDBY button while simultaneously pressing SURROUND MODE and AUTO
buttons.
3.
Check that the entire display is
fl
ashing with an interval of about 1 second, and release your
fi
ngers from the 2
buttons and the microprocessor will be initialized.
Service Jigs
When you repair the printing board, you can use the following JIG (Extension cable kit).
Please order to marantz Of
fi
cial Service Distributor in your region if necessary.
8U-110084S :
EXTENSION UNIT KIT
: 1 Set
(Refer to "JIG FOR SERVICING".)
Note:
•
If step 3 does not work, start over from step 1.
•
All user settings will be lost and this factory setting will be recovered when this initialization mode.
So make sure to memorize your setting for restoring after the initialization.
ON/STANDBY
SURROUND MODE
AUTO
Summary of Contents for AV7005/N1B
Page 62: ...62 Personal notes ...
Page 64: ...64 BLOCK DIAGRAM ...
Page 139: ...139 R5F3650KNFB HDMI U5500 ...
Page 146: ...146 IS42S32200E6TL HDMI U1602 IS42S32200E6TL Block diagram ...
Page 155: ...155 AK4424ET HDMI U3800 U3801 AK4424ET Block Diagram ...
Page 156: ...156 AK5358BET HDMI U3802 AK5358BET Pin Function ...
Page 160: ...160 HY27UF081G2A TPCB Block Diagram ...
Page 170: ...170 2 FL DISPLAY FLD 19 ST 02GINK FRONT Z1001 PIN CONNECTION GRID ASSIGNMENT ...
Page 171: ...171 ANODE CONNECTION ...
Page 172: ...172 VFD GP1261AI FRONT Z1002 PIN CONNECTION PATTERN DETAIL ...