NOTE B
For importing External FIR Calculated coefficients into the MARANI
LPP260A
, the file format has to be
the following:
FIR FILE FORMAT
- Standard floating point txt file
- One coefficient for each row
- Decimal separator: "."
- Max coefficient value: 4.0
- Max filter length (i.e. max file rows): Up to 1024 taps (shorter filters are allowed)
Just to be make sure, here below an example of "FIRFormat.txt" which can be imported by the
LPP260A
:
FIRFormat.txt
-2.65204521320808E-06
-2.1021137868951E-06
-1.21276289563775E-06
6.87446664056699E-20
1.48474417799171E-06
3.15405377541534E-06
4.88738331652021E-06
6.53749187280831E-06
7.94029938736576E-06
8.92767141156887E-06
9.34231057722965E-06
9.05364538873791E-06
7.97338946695563E-06
6.06932382028795E-06
3.37585149784821E-06
-3.4267786230259E-20
-3.87819635557018E-06
-8.01162412259308E-06
-1.20985410917215E-05
-1.5801217026279E-05
-1.87698608816692E-05
-2.06703793366999E-05
-2.12140299515895E-05
-2.01866684942683E-05
-1.74750861611266E-05
-1.30879209253108E-05