Manson Engineering Industrial SBC-8138 User Manual Download Page 6

G.  Temperature Sensor   

 

Warning! 
The temperature sensor must be installed at the Negative Terminal of the battery terminal, wrong connection to 
the Positive Terminal will damage the charger and the sensor. See below Fig.5 for installation. 

 

The temperature sensor is used to optimal charging over wide ambient temperature range. 
Fix the temperature sensor in a position on the battery which is not affected by other cooling or heating source. Or you 
can insert it into the power cable negative battery clamp (factory pre-mounted) 
The reference temperature of this sensor is 25°C and compensation voltage is -20mV/C for SBC-8138 and -40mV/C for 
SBC-8238, the higher the battery temperature, the lower the charging voltage. When battery temperature reaches 60°C, 
the charger will shutdown, Fault and OTP indicator will light up. 

 

 

 
 

H.    Fault Indication 

 

Fault LED (Red)

Solid for F1/ 2/ 4 

Flashing for F3/ 5/ 6/ 7/ 8

 

 
 

Fault type  Protection/ Fault Description 

 

F1 

Charger over temperature protection 

 

F2 

Output over voltage (tracking) 

 

F3 

Overload (OCP), 10% higher than the C.C. 

 

F4 

Fan stuck or not working 

 

F5 

Faulty battery 

 

F6 

Battery temp over 60°C as detected by remote sensor 

 

F7 

short circuit > 5 sec shut down otherwise auto-recover 

 

F8 

Reverse polarity 

 

Remark: F7 is only for power supply

 

 

 
 
 

Fig.5 

Summary of Contents for SBC-8138

Page 1: ...not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face awa...

Page 2: ...ensure a durable working life span even in harsh conditions for the charger and the battery There are selections for WET AGM GEL and Calcium Calcium battery types Special evaluation conditioning charg...

Page 3: ...tive or Deep Cycle lead acid batteries Calcium Calcium Sealed type VRLA Lead Acid batteries with Calcium content Automotive or Deep Cycle Power Supply to provide a constant voltage DC power 13 3V to t...

Page 4: ...lting in a huge voltage drop between the battery charger to the load D Normal Multi Stage IUoU Charging Operation The 7 stage IU0U charge algorithm ensures fast complete and at the same time gentle ch...

Page 5: ...ood condition The standby auto new cycle charge per 18 days are designed to keep the battery in good working condition during long period of resting of the caravan or back up battery application E Rec...

Page 6: ...ference temperature of this sensor is 25 C and compensation voltage is 20mV C for SBC 8138 and 40mV C for SBC 8238 the higher the battery temperature the lower the charging voltage When battery temper...

Page 7: ...lect switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for loose contact right cable s...

Page 8: ...le Noise Peak to Peak 200mV Efficiency at WET 230VAC 85 Protections Short Circuit Protection Yes Overload Protection Yes Reverse Polarity Protection by Mosfet Yes Over Temperature Protection Yes OVP O...

Reviews: