Manson Engineering Industrial SBC-8138 User Manual Download Page 3

 

Recondition LED (Orange) 

 

:  Charging with preset constant voltage and only for Wet type battery 

 
 

Power supply LED (Blue) 

 

:  Output 13.3V and max current 

 
 

Fault LED (Red) 

 

:  Charger malfunction (See below section H) 

 

 

 

 

 

2.  Programming Port 

 

Factory use only 

 

3.  Recondition mode switch 

 

Simple press and hold 3 seconds the switch to set the charger to go with recondition charge in next cycle. 

 

4.  Battery selection switch 

 

For Wet, AGM, GEL, Calcium-Calcium and Power supply mode. (Default at position 3 the GEL type) 

 

5.  Charging current selection switch (Manual de-rating) 

 

Current can be selected to 20%, 40%, 60%, 80% and 100% of the max current. Details please see the label 

 

under the moveable door. (Default at 100%) 

 

6.  Charging cable with removable temperature sensor 

 

RED battery clamp– Battery positive pole 

 

BLACK battery clamp– Battery negative pole 

 

7.  Removable temperature sensor 

 

To increase/ decrease charging voltage at low/ high battery temperature 

 
8.  Ventilation Fan 

 

Thermostatic control fan from zero to full speed 

 

9.  AC input power cord 
 

B.  Battery Type Selection 

 
Make sure the charger is power OFF, use a small slot type screw driver to select the battery through Battery Selection 
Switch (4). 
 
WET 

:  Flooded Type lead acid batteries (to which water can be added) Automotive or Deep Cycle 

AGM/GEL 

:  Sealed type (VRLA), AGM-GEL, Maintenance Free, Automotive or Deep Cycle lead acid batteries 

Calcium-Calcium  :  Sealed type (VRLA) Lead Acid batteries with Calcium content Automotive or Deep Cycle 
Power Supply 

:  to provide a constant voltage DC power 13.3V to the external load connected to the battery and at   

 

 

  the same time without over charging the battery 

 

B1.  Recommended Battery Capacity   

 
The  following  minimum  AH  capacities  are  a  generalized  suggestion,  some  batteries  can  take  higher  charge  current, 
check with battery manufacturers for charging batteries with smaller capacity.   

 

C.   Battery Charger Installation and Connection 

 
Observe the warnings & safety precautions before rushing to install and operate the charger. 
Check battery condition, fill up cells for wet battery, clean battery poles. 
Secure  the battery  charger in a  well  ventilated  place, make sure the mounting  surface is flat and  without  soft covering 
material or loose paper sheet. The air intake is at the left side and air outlet at the right side. Make sure both intake and 
outlet are not blocked. Never place charger on top of battery. 
 
Plug in the AC mains. All the indicators on the front panel will lit up, cooling fan spins at full speed for  3  seconds and a 
“Beep” sound by means of Self-Testing. 
Once Self-Testing completed, the status LEDs will lit up sequence in case of no battery connected. 
Once battery connected, status LEDs all lit up for 5 seconds so to check battery status before start charging. 
 
 
 
 
 

Charger Model 

SBC-8138 , 12V/25A 

SBC-8238 , 24V/13A 

Battery Capacity 

20 AH - 250 AH   

10 AH - 125 AH 

Summary of Contents for SBC-8138

Page 1: ...not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face awa...

Page 2: ...ensure a durable working life span even in harsh conditions for the charger and the battery There are selections for WET AGM GEL and Calcium Calcium battery types Special evaluation conditioning charg...

Page 3: ...tive or Deep Cycle lead acid batteries Calcium Calcium Sealed type VRLA Lead Acid batteries with Calcium content Automotive or Deep Cycle Power Supply to provide a constant voltage DC power 13 3V to t...

Page 4: ...lting in a huge voltage drop between the battery charger to the load D Normal Multi Stage IUoU Charging Operation The 7 stage IU0U charge algorithm ensures fast complete and at the same time gentle ch...

Page 5: ...ood condition The standby auto new cycle charge per 18 days are designed to keep the battery in good working condition during long period of resting of the caravan or back up battery application E Rec...

Page 6: ...ference temperature of this sensor is 25 C and compensation voltage is 20mV C for SBC 8138 and 40mV C for SBC 8238 the higher the battery temperature the lower the charging voltage When battery temper...

Page 7: ...lect switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for loose contact right cable s...

Page 8: ...le Noise Peak to Peak 200mV Efficiency at WET 230VAC 85 Protections Short Circuit Protection Yes Overload Protection Yes Reverse Polarity Protection by Mosfet Yes Over Temperature Protection Yes OVP O...