Stage 4. 

ABSORPTION CHARGE - The constant voltage charging   

 

Battery Type Selection: Wet: 14.4V, AGM: 14.3V, Gel: 14.1V, Calcium: 15.1V 
When the battery voltage rises to the selected Absorption voltage level, the charging will switch to Constant voltage 

charging. Absorption LED 

  is ON. Absorption charging current will decrease gradually to a set value at which the 

charger automatically switches to Float Stage.   
The max. absorption time is also controlled by the time in Bulk charge and battery type selected. 
 
Remark:  There is no charging at the end of Absorption charge. 
 

 

This is normal as the battery you connected is under analysis.

 

 
Stage 5.   

RECONDITION CHARGE - The constant voltage charging 

 
Only for WET battery and manual select, please refer to section E. 

 
Stage 6. 

FLOAT CHARGE - The constant voltage charging 

 
In this stage, the battery is full and only takes in the amount of current necessary for maintaining the capacity. The float 

voltage is preset by factory according to the type of battery. Float LED 

  is ON. 

In  case  of  the  charger  keeps  at  this  mode  with  charging  current  less  than  20%  of  bulk  current  for  over  60  hours.  The 
charger will go into the Standby mode.   
 

Stage 7. 

STANDBY MODE - The constant voltage charging 

   
In this stage, the charging voltage at this mode will be 4% less than the Float voltage only for maintaining the capacity. 

Float LED 

  is slow flashing. 

 

New Cycle Charge every 18 days 

Charger will start a new cycle charging of bulk to absorption to float every 18 days in either standby or float mode This 
new cycle of charging will refresh the battery to prevent separation of the electrolyte & keep the electrode plates in good 
condition. 
The standby auto new cycle charge per 18 days are designed to keep the battery in good working condition during long 
period of resting of the caravan or back up battery application. 

 

E.  Recondition Charging for wet type battery only 

 
This mode is used to recover  deeply  discharged flooded battery only by high voltage charging (about  10% overcharge 
absorption voltage). You can manual select this mode by simply press and hold 3 seconds the Recondition mode switch 
(3)  to  set  the  charger  at  the  beginning  of  charging  operation.  The  Recondition  LED  will  lit  up  to  represent  you  have 
selected Recondition mode in this charging cycle and the charging will be conducted after Absorption mode. 
After entered into this mode, only the Recondition LED will ON. This will put the charger keep at Recondition mode for 
preset time and then charger will go to Float once completed. 
In  case  you  want  to  cancel  the  Recondition  charge  that  you  selected,  you  can  disable  this  by  press  and  hold  the 
Recondition mode switch (3) for 3 seconds. 
 

Remark:    1.  This mode only can be operated at Flooded battery selected (Battery Selection Switch (4) set to   
 

 

 

position 1 the WET battery) 

 

 

2.  Take special precautions as battery will emit explosive gas during Recondition charge. 

 
F.  Power Level adjustment 

 
End user can set the maximum output current so to make the charger can suitable for different capacity battery 
Make sure the charger is power OFF before adjust the power level. 
Use a small slot type screw driver to select the maximum output current through the Charging Current Selection Switch 
(5). Please refer to the label under the removable door for power level selection. 
 
Position 1: 100% of the rated current 
Position 2: 80% of the rated current   
Position 3: 60% of the rated current   
Position 4: 40% of the rated current   
Position 5: 20% of the rated current   
 

 

 

Summary of Contents for SBC-8138

Page 1: ...not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face awa...

Page 2: ...ensure a durable working life span even in harsh conditions for the charger and the battery There are selections for WET AGM GEL and Calcium Calcium battery types Special evaluation conditioning charg...

Page 3: ...tive or Deep Cycle lead acid batteries Calcium Calcium Sealed type VRLA Lead Acid batteries with Calcium content Automotive or Deep Cycle Power Supply to provide a constant voltage DC power 13 3V to t...

Page 4: ...lting in a huge voltage drop between the battery charger to the load D Normal Multi Stage IUoU Charging Operation The 7 stage IU0U charge algorithm ensures fast complete and at the same time gentle ch...

Page 5: ...ood condition The standby auto new cycle charge per 18 days are designed to keep the battery in good working condition during long period of resting of the caravan or back up battery application E Rec...

Page 6: ...ference temperature of this sensor is 25 C and compensation voltage is 20mV C for SBC 8138 and 40mV C for SBC 8238 the higher the battery temperature the lower the charging voltage When battery temper...

Page 7: ...lect switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for loose contact right cable s...

Page 8: ...le Noise Peak to Peak 200mV Efficiency at WET 230VAC 85 Protections Short Circuit Protection Yes Overload Protection Yes Reverse Polarity Protection by Mosfet Yes Over Temperature Protection Yes OVP O...

Reviews: