Maintenance plan 

6.2

 

Maintenance  of  the  main  filter 
element 

 

Maintenance of the main filter 
element (Pos. 2) need only be 
performed when the maintenance 
indicator/switch has been triggered 
or according to the device or engine 
manufacturer's instructions. 

 

Regardless of the number of 
operating hours, the main filter 
element must be changed after 2 
years at the latest. 

Never continue to use damaged 
main filter elements.  

In case of doubt, always install a 
new main filter element. 

 

6.2.1

 

Disassembling the main filter 
element 

 

Unlock  the  wire  clamp  fasteners  (Pos.  9) 
and remove the housing cover (Pos. 1). 

 

Remove the main filter element (Pos. 2) and 
dispose of it according to local regulations. 

 

Clean  the  inside  of  the  housing,  frame  and 
lid thoroughly with a damp cloth. In the case 
of  filters  without  a  secondary  element,  pay 
particular  attention  here  that  no  dust  or  dirt 
gets into the clean air side of the filter. 

 

Check all the parts for signs of damage and 
wear, replace them as necessary. 

IQORON series 10, 12 and 14: 

 

Move  the  red  clamping  bar  towards 
"Unlock" (refer to Fig. 4). 

 

Remove  the  frame  (Pos.  11)  together  with 
the main filter element (Pos. 2). 

 

Remove  the  main  filter  element  from  the 
frame  and  dispose  of  it  according  to  the 
local regulations.  

 

6.2.2

 

Cleaning the main filter element 

 

Never wash out or beat the main 
filter element.  
When blowing clean, ensure no 
dust gets into the inside of the main 
filter element. 

 

Since small defects are difficult to 
detect or cannot be detected, we 
recommend always installing new 
elements to protect engines or 
equipment! 

We assume no liability for the 
suitability of cleaned elements. 

 

Clean 

the 

main 

filter 

element 

with 

compressed  air  (maximum  5  bar)  carefully, 
applying the compressed air from the clean 
side  (seal  side)  until  no  more  dust 
development  occurs.  The  tip  of  the 
compressed  air  gun  must  not  touch  the 
main filter element. 

 

 

Fig. 4 

Unlocking the main filter element frame  

 

Fig. 5 

Cleaning the IQORON main filter element 

(Fig. illustrates size 7) 

Summary of Contents for IQORON 10

Page 1: ...Version 0709 MANN HUMMEL IQORON 7 10 12 14 Installation and Maintenance Manual...

Page 2: ...block 10 7 Storing Filter Elements 10 8 Troubleshooting 11 9 Disposing of Parts 12 1 Foreword This installation and maintenance manual serves to help you become familiar with the IQORON and its intend...

Page 3: ...eyond this such as filtering aggressive combustible and or explosive materials is considered unintended use The manufacturer supplier is not considered liable for damage resulting from unintended use...

Page 4: ...the filter must be serviced The secondary element Pos 10 protects the engine from penetration by dust during maintenance and to a certain extent during operation with a main filter element damaged th...

Page 5: ...comparable Pos Name Pos Name 1 Lid 7 Connection for maintenance indicator switch 2 Main filter element 8 Clean air connection 3 Cyclone block 9 Wire clamp fastener 4 Allen screw 10 Secondary element 5...

Page 6: ...sing screws or stud bolts washers and self locking nuts M8 tightening torque 10 2 Nm Depending on the version threaded inserts M8 and or fixation eyelets are provided on the filter for this purpose Sl...

Page 7: ...air filter to ejector Check for damage leaks Monthly and after repair work Cyclone block Check for signs of damage and clean According to conditions of use and type of contamination Plastic housing an...

Page 8: ...irt gets into the clean air side of the filter Check all the parts for signs of damage and wear replace them as necessary IQORON series 10 12 and 14 Move the red clamping bar towards Unlock refer to F...

Page 9: ...Fig 7 and mount the lid Fit the wire clamp fasteners in the slot in the flange on the housing and lock them 6 3 Maintenance of the secondary element The secondary element must be changed every 5th mai...

Page 10: ...oreign bodies and dust deposits from the cyclone block and inside the housing by hand or by means of a brush for example Loosen stubborn dust deposits on the cyclone block by soaking in a PA6 compatib...

Page 11: ...if necessary refer to Section 6 Incorrect maintenance Remove dust thoroughly complete maintenance in accordance with Section 6 Housing not sealed properly Remove dust thoroughly check main filter elem...

Page 12: ...GF 30 Plastics recycling center Secondary element Filter paper Polyurethane foam Adhesive PA 6 Dispose of according to local regulations Housing lid PA 6 GF30 Plastics recycling center Housing with w...

Page 13: ...MANN HUMMEL Industrial Filters 13 Notes MANN HUMMEL GMBH Gesch ftsbereich Industriefilter 67346 Speyer Germany Telephone 49 62 32 53 80 Fax 49 62 32 53 88 99 E mail if info mann hummel com Internet w...

Reviews: