Section 4
Maintenance
17
15. Remove three thumbscrews, then remove bin cover.
16. Remove agitator bar and ice breaker on RNS020.
NOTE: Bar must be reassembled by inserting front edge
into the paddle wheel, then lowering the back edge
(rounded 90 angle) to prevent water leakage into the
compressor compartment.
17. Remove ice deflector.
A. Remove the two thumbscrews.
B. Lift the ice deflector out.
18. Remove ice dispensing wheel by lifting straight out.
19. Remove the water reservoir cover.
A. Push up on cover to snap off.
20. Mix a solution of cleaner and warm water.
Depending upon the amount of mineral buildup, a
larger quantity of solution may be required. Use the
ratio in the table below to mix enough solution to
thoroughly clean all parts.
21. Use the cleaner/water mixture to clean all
components. The cleaner solution will foam when it
contacts lime scale and mineral deposits; once the
foaming stops use a soft-bristle nylon brush, sponge
or cloth (NOT a wire brush) to carefully clean the
parts. Soak parts for 5 minutes (15 - 20 minutes for
heavily scaled parts). Rinse all components with
clean water.
Remove Thumbscrews
RNS012
-
Remove Thumbscrew &
Agitator Bar
RNS020
-
Remove Upright Agitator
& Agitator Bar Then Ice Breaker
Thumbscrews, Bolts & Breaker Bar
Remove
Wingnuts
Solution Type
Water
Mixed With
Cleaner
1 gal. (4 l)
16 oz (500 ml) cleaner
!
Caution
Do not pour cleaner or sanitizer solutions into the
bin. The solution will leak out of the front of the bin
and into the compressor compartment.