![Manitowoc RF0300 Technician'S Handbook Download Page 29](http://html.mh-extra.com/html/manitowoc/rf0300/rf0300_technicians-handbook_701084029.webp)
29
Step 7
Move the toggle switch to the ON position.
The ice machine will make ice with the cleaning solution
and deposit the ice in the bin. Add the remaining cleaner/
water solution as the water level in the reservoir drops.
NOTE: Do not allow the cleaner/water level to drop
below the minimum water level. The ice machine will
discontinue the cleaning cycle if the water float switch
opens.
Step 8
After all of the cleaner/water solution has been
added turn on the ice making water supply. Continue
the freeze cycle for 10 minutes to remove the cleaning
solution from the water circuit.
Step 9
Place the toggle switch in the OFF position.
Step 10
Refer to disassembly for cleaning/sanitizing
and remove parts for hand cleaning/sanitizing.
• Hand clean all parts
• Rinse all parts with clear potable water
• Sanitize all parts - do not rinse after sanitizing
• Spray all interior bin surfaces with sanitizer (do not
rinse sanitized areas).
• Spray evaporator discharge spout
Step 11
Reassemble ice machine.
Step 12
Turn off the ice making water supply.
Summary of Contents for RF0300
Page 1: ...Part Number 000007661 11 16 R Model Flake Nugget Ice Machine Technician s Handbook ...
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 20: ...THIS PAGE INTENTIONALLY LEFT BLANK 20 Part Number 000007661 11 16 ...
Page 26: ...THIS PAGE INTENTIONALLY LEFT BLANK 26 Part Number 000007661 11 16 ...
Page 172: ...THIS PAGE INTENTIONALLY LEFT BLANK 172 Part Number 000007661 11 16 ...
Page 218: ...THIS PAGE INTENTIONALLY LEFT BLANK 218 Part Number 000007661 11 16 ...
Page 222: ...222 Part Number 000007661 11 16 RF0300 AIR COOLED Refer to Nameplate for Voltage Rating ...
Page 230: ...230 Part Number 000007661 11 16 RF1200 WATER COOLED Refer to Nameplate for Voltage Rating ...
Page 240: ...240 Part Number 000007661 11 16 Condensing Units RCU CONDENSING UNIT 1PH ...
Page 241: ...Part Number 000007661 11 16 241 RCU CONDENSING UNIT 3PH ...
Page 248: ...248 Part Number 000007661 11 16 RNS0308 AIR COOLED Refer to Nameplate for Voltage Rating ...
Page 256: ...256 Part Number 000007661 11 16 RNS1000 AIR COOLED Refer to Nameplate for Voltage Rating ...
Page 266: ...266 Part Number 000007661 11 16 RF1200 RFS1200 WATER COOLED 1 2 3 4 5 6 7 8 ...
Page 268: ...268 Part Number 000007661 11 16 RF2300 RFS2300 AIR COOLED 1 2 3 4 5 6 7 8 8 ...
Page 270: ...270 Part Number 000007661 11 16 RF2300 RFS2300 WATER COOLED 1 2 3 4 5 6 7 8 8 ...
Page 278: ...278 Part Number 000007661 11 16 RN0400 RN1000 RN1400 AIR WATER COOLED 1 2 3 4 5 6 ...
Page 282: ...THIS PAGE INTENTIONALLY LEFT BLANK 282 Part Number 000007661 11 16 ...
Page 283: ......