Section 3
Ice Machine Operation
3-3
Operational Checks
GENERAL
Your Manitowoc ice machine was factory-operated
and adjusted before shipment. Normally, a newly
installed ice machine does not require any
adjustment.
To ensure proper operation, always follow these
Operational Checks when starting the ice machine:
•
for the first time
•
after a prolonged out of service period
•
after cleaning and sanitizing
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.
WATER LEVEL
The water level sensor is set to maintain the proper
water level above the water pump housing. The water
level is not adjustable.
If the water level is incorrect, check the water level
probe for damage (probe bent, etc.). Repair or replace
the probe as necessary.
Water Level Probe
ICE THICKNESS CHECK
After a harvest cycle, inspect the ice cubes in the ice
storage bin. The ice thickness probe is factory-set to
maintain an ice bridge of 1/8 inch (3.2mm). If an
adjustment is needed, follow the steps below.
1.
Turn the ice thickness probe adjustment screw
clockwise for a thicker ice bridge, or
counterclockwise for a thinner ice bridge.
IMPORTANT
It is normal for cubes to have a slight dimple. This
is a normal characteristic associated with
Manitowoc’s unique shape.
Ice Thickness Adjustment
2.
Make sure the ice thickness probe wire and
bracket do not restrict movement of the probe.
SV1208
SV1616
1/8” ICE
THICKNESS
ADJUSTING
SCREW
WATER
PUMP
WATER LEVEL
SENSOR PROBE
WATER PUMP
IMPELLER HOUSING
PUMP
OUTLET