Safe Installation Dos and Don’ts
•
DO
adhere to all National and Local Plumbing and
Electrical Safety Codes.
•
DO
turn OFF incoming electrical service switches
when servicing, installing, or repairing equipment.
•
DO
check that all flare fittings are tight. This check
must be performed with a wrench to ensure a quality
seal.
•
DO
inspect pressure on regulators before starting up
equipment.
•
DO
protect eyes when working around refrigerants.
•
DO
use caution when handling metal surface edges
of all equipment.
•
DO
handle CO
2
cylinders and gauges with care.
Secure cylinders properly against abrasion.
•
DO
store CO
2
cylinder(s) in well ventilated areas.
•
DO NOT
exhaust CO
2
gas (example: syrup pump)
into an enclosed area, including all types of walk-in
coolers, cellars, and closets.
•
DO NOT
throw or drop a CO
2
cylinder. Secure the
cylinder(s) in an upright position with a chain.
•
DO NOT
connect the CO
2
cylinder(s) directly to the
product container. Doing so will result in an explosion
causing possible death or injury. It is best to connect
the CO
2
cylinder(s) to a regulator(s).
•
DO NOT
store CO
2
cylinders in temperature above
125°F (51.7°C) near furnaces, radiator or sources of
heat.
•
DO NOT
release CO
2
gas from old cylinder.
•
DO NOT
touch refrigeration lines inside units; some
may exceed temperatures of 200°F (93.3°C).
NOTICE:
All utility connections and fixtures must be
sized, installed, and maintained in accordance with
Federal, State, and Local codes.
!
Warning
Read the following warnings before beginning an
installation. Failure to do so may result in possible
death or serious injury.
Summary of Contents for MULTIPLEX 11M
Page 6: ...Table of Contents continued iv Part Number 020001552 5 11 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...Operation Section 3 3 4 Part Number 020001552 5 11 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...Maintenance Section 4 4 4 Part Number 020001552 5 11 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 41: ......