68
Part Number 040005626 5/17
Discharge Pressure High Checklist
Improper Installation
•
Refer to “Installation/Visual Inspection Checklist”
on page 55.
Condenser Air Flow
•
High inlet air temperature
•
Condenser discharge air re-circulation
•
Dirty condenser fins
•
Defective fan cycling control
•
Defective fan motor
Improper Refrigerant Charge
•
Overcharged
•
Non-condensible in system
•
Wrong type of refrigerant
Other
•
Non-OEM components in system
•
High side refrigerant lines/component restricted
(before mid-condenser)
Freeze Cycle Discharge Pressure Low Checklist
Improper Installation
•
Refer to “Installation/Visual Inspection Checklist”
on page 55.
Improper Refrigerant Charge
•
Undercharged
•
Wrong type of refrigerant
Other
•
Non-OEM components in system
•
High side refrigerant lines/component restricted
(before mid-condenser)
•
Defective fan cycle control
NOTE: Do not limit your diagnosis to only the items
listed in the checklists.
Summary of Contents for MD0420A
Page 2: ......
Page 28: ...28 Part Number 040005626 5 17 This Page Intentionally Left Blank ...
Page 40: ...40 Part Number 040005626 5 17 This Page Intentionally Left Blank ...
Page 48: ...48 Part Number 040005626 5 17 This Page Intentionally Left Blank ...
Page 86: ...86 Part Number 040005626 5 17 This Page Intentionally Left Blank ...
Page 126: ...126 Part Number 040005626 5 17 This Page Intentionally Left Blank ...
Page 128: ...128 Part Number 040005626 5 17 M0420 M0500 M0700 M1000 1 PH SELF CONTAINED AIR WATER COOLED ...
Page 131: ......