Part Number 040005626 5/17
25
Water Service/Drains
WATER SUPPLY
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
WATER INLET LINES
Follow these guidelines to install water inlet lines:
•
Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on
sink faucets, dishwashers, etc.)
•
If water pressure exceeds the maximum
recommended pressure, 80 psig (5.5 bar) obtain a
water pressure regulator from your Manitowoc
distributor.
•
Install a water shut-off valve for ice making potable
water.
•
Insulate water inlet lines to prevent condensation.
Important
If you are installing a water filter system, refer to
the Installation Instructions supplied with the filter
system for ice making water inlet connections.
!
Warning
For ice making, connect to a potable water supply
only.