![Manitowoc Marine Q 1000 Service Manual Download Page 29](http://html.mh-extra.com/html/manitowoc/marine-q-1000/marine-q-1000_service-manual_701043029.webp)
25
Electrical System
Problem: Water Trough Overfilling During The Freeze Cycle (continued)
Step 3 Allow ice machine to run. Disconnect the water level probe from control board terminal 1F, and
connect a jumper wire from terminal 1F to any cabinet ground.
Remember if you are past 6 minutes from starting, the ice machine will go into a freeze cycle water inlet
valve safety shut-off mode, and you will be unable to complete this test. If past 6 minutes you must restart
this test by disconnecting the jumper wire, restarting the ice machine, (step 1) and then reinstalling the
jumper wire to terminal 1F, after the compressor starts.
Step 3
HARVEST/SAFETY LIMIT LIGHT
WATER LEVEL LIGHT
BIN SWITCH LIGHT
CLEAN LIGHT
YELLOW
GREEN
GREEN
RED
1C
1G
GROUND
JUMPER
1F
SV1588
Step 3 Jumper wire connected from control board terminal 1F to ground
The Water Inlet
Valve Solenoid
Coil is:
Is water flowing
into the water
trough?
The Water Level
Light is:
Cause
no on
De-Energized
The water level probe is causing the problem.
Clean or replace the water level probe.
yes
off
Energized
The control board is causing the problem.
yes
on
De-Energized
The water fill valve is causing the problem.
Summary of Contents for Marine Q 1000
Page 60: ...56 Refrigeration System Section 7 ...
Page 61: ......