OPERATING CONTROLS AND PROCEDURES
3
•
RCL Bypass Active Indicator is on
•
RCL Bypass Status Indicator is on
•
RCL Lockout LED is flashing
•
3rd Wrap Indicator is flashing
•
Working Range Limiter (WRL) Indicator is flashing
•
Carrier Avoidance Indicator is flashing
•
-29°C Temperature Limiter Indicator is flashing
All craning functions locked out are bypassed while the Limit
Bypass switch is held in the actuated position.
Limit Bypass Switch (CE Certified Cranes)
T h e R a t e d C a pa c i t y L i m i t e r ( R C L ) s y s t e m , w h e n
programmed accurately, will lockout the following crane
functions—boom up/down, telescope extend, and hoist up—
when a lift is attempted at or above the crane's capacity, or
when a two-block condition exists. Locking out these
functions prevents the overload or two-block condition from
worsening. These same craning functions are locked out
initially when starting the crane and before the RCL system
has been programmed.
The Limit Bypass Switch (19) (Figure 3-6) is a three-position,
momentary type key switch. In an emergency situation only,
turn switch clockwise or counterclockwise to bypass the
different limiter systems on the crane.
Turn key switch clockwise and release to bypass the
following limiter systems and their craning function lockouts:
•
Anti-Two-Block System (boom up/down, telescope
extend, hoist up)
•
3rd Wrap Limiter System (hoist down)
The following indicators illuminate to indicate the limiters are
bypassed:
•
3rd Wrap Indicator is flashing
•
Anti-Two-Block Indicator is flashing
When switch is turned clockwise and released, all crane
functions—boom up/down, telescope extend/retract, hoist
up/down, and swing left/right—will operate at 50% of normal
speeds when actuated.
Turn key switch counterclockwise and release to bypass the
following limiter systems and their craning function lockouts:
•
RCL system (boom up/down, telescope extend, hoist
up)
•
Working Range Limiter (WRL) system
•
Carrier Avoidance system
•
-29°C Temperature Limiter system (optional)
If the RCL is programmed and active and the limit bypass
switch is turned counterclockwise and released. The swing
left/right function speed is reduced to 25% when actuated.
The boom up/down, hoist up/down, and telescope extend/
retract function speeds are reduced to 15% of rated function
speed when actuated. If load exceeds 110% of crane
capacity, all craning functions will lock out. The following
indicators illuminate to indicate the limiters are bypassed:
•
Bypass 1 Pressed Indicator is on (only when switch is in
the counterclockwise position)
•
Bypass 1 Active Indicator is on
•
RCL Bypass Active Indicator is on
•
RCL Bypass Status Indicator is on
•
RCL Lockout LED is flashing
•
Working Range Limiter (WRL) Indicator is flashing
•
Carrier Avoidance Indicator is flashing
•
-29°C Temperature Limiter Indicator is flashing
If the RCL has not been programmed and the limit bypass
switch is turned counterclockwise and released, the swing
left/right, boom up/down, hoist up/down, and telescope
extend/retract functions operate at normal speeds when
actuated. The following indicators illuminate to indicate the
limiters are bypassed:
•
Bypass 1 Pressed Indicator is on (only when switch is in
the counterclockwise position)
•
Bypass 1 Active Indicator is on
•
RCL Bypass Status Indicator is on
•
RCL Lockout LED is flashing
•
Working Range Limiter (WRL) Indicator is flashing
•
Carrier Avoidance Indicator is flashing
•
-29°C Temperature Limiter Indicator is flashing
All craning functions locked out are bypassed until one of the
following occurs:
•
Limit Bypass Switch is again turned to the
counterclockwise position and released while the
joysticks are in the neutral position
•
Joysticks are in neutral position for 10 seconds
WARNING
Loss of RCL Monitoring Hazard!
The Limit Bypass Switch is to be used to override the RCL
system in emergency situations only.
Do not operate the crane with the RCL overridden during
normal operations.
Summary of Contents for Grove GRT880
Page 1: ...Operator Manual Grove GRT880 8968 ...
Page 4: ...THIS PAGE BLANK ...
Page 10: ...TABLE OF CONTENTS GRT880 TOC 6 THIS PAGE BLANK ...
Page 16: ...INTRODUCTION GRT880 OPERATOR MANUAL 1 6 Published 3 25 2020 Control 643 04 THIS PAGE BLANK ...
Page 200: ...OPERATOR MANUAL GRT880 6 2 THIS PAGE BLANK ...
Page 201: ......
Page 202: ......