Document Number: 000013527 Rev02  04/19

Subject: K00459 S Model Bin Thermostat 

,

Caution

The thermostat must be wired to match the voltage of 
the ice machine. The thermostat is factory wired for 115 
volts. Rewire thermostat, if your ice machine is 240 volts.

10.  The control box line voltage wiring offers two options:

Connect thermostat L1 (brown) and L2 (blue)
wires to contactor (incoming line voltage side)
L1 and L2.

OR

Disconnect incoming power line wire nuts.
Remove quick-connect fittings from brown and
blue wires and strip 1/2” of insulation from the
wires.  Connect incoming power L1, ice machine
L1, and thermostat L1 (brown) wires together
with wire nut. Connect incoming power L2, ice
machine L2, and thermostat L2 (blue) wires
together with wire nut..

11. Connect bin switch wires:

Manitowoc Models

A.

Disconnect the red male/female connector bin
switch wire and connect the red male wire from
the controller to the red female bin switch wire.

B.

Connect the white male bin switch wire to the
white female wire of the controller.

KoolAire Models

A.

Cut the red bin switch wire 3 inches from molex
connector on bin switch.

B.

Strip wires and install male and female crimp
connectors  supplied in kit.

C.

Connect male and female connectors from the bin
thermostat into the newly installed terminals.

12. Restore all power to the ice machine and dispenser at

the service-disconnect or fuse/breaker panel.

13. The factory setting on the thermostat will be correct for

most applications.

14. With two screws, secure the controller bracket

assembly to the flange of the bulkhead.

15. Reinstall the control box cover and all panels.

CONTROLLER WIRING

CONTROL SETTINGS

The controller has a one-minute time delay anytime power 
is interrupted and restored.

TOUCH PAD LOCK

P5 Jumper

The P5 jumper position determines if the touch pad is 
locked or unlocked. The control is factory locked; to unlock, 
move the jumper from one pin to two pins.

115V

240V COM

NC

NO

C

P5

P4

Red Sensor Lead

Black Sensor Lead Text

Match Wiring 
To Ice Machine 
Voltage

Bin Switch
Or
Toggle Switch
Connections

Summary of Contents for FS9000

Page 1: ...00 or FS9100 FS9000 Assembly and Mounting 1 Move the ice machine and dispenser away from the wall for easier access 2 Bracket selection A Dual evaporator ice machines Use bracket with the shorter top flange B Single evaporator ice machines Use bracket with the longer top flange 3 Remove all panels and control box cover from the ice machine 4 If an ice machine is already installed on the dispenser ...

Page 2: ...nge before re fastening close gap FS9000 FS9100 Continued 7 Route thermistor wire out towards the back of the dispenser Remove unused 7 8 diameter knockout on the back panel snap fit the bushing over the exposed panel hole and route wire into the ice machine control board compartment Internally the cable must be routed as to avoid contact with high voltage high heat or sharp objects 8 Normally the...

Page 3: ... switch wire B Connect the white male bin switch wire to the white female wire of the controller KoolAire Models A Cut the red bin switch wire 3 inches from molex connector on bin switch B Strip wires and install male and female crimp connectors supplied in kit C Connect male and female connectors from the bin thermostat into the newly installed terminals 12 Restore all power to the ice machine an...

Page 4: ...e display then returns to the sensor temperature CHECK PROCEDURE If the control system does not function properly verify that the control is wired and set up properly If the problem persists use the following procedures to determine the cause of the problem nWarning Line voltage is present inside the control Contact with line voltage can cause injury or death Follow these troubleshooting procedure...

Page 5: ... the sensor leads and supply power to the control C Replace the cover D Check the control settings for proper values E Press and hold MENU until SP appears F Press up and down arrows to change the set point temperature above and below the sensor temperature until the relay energizes and de energizes G If the output relay does not perform as indicated replace the control H If proper operation of th...

Reviews: