Manitowoc FS9000 Instruction Sheet Download Page 2

2 of 5
Document Number: 000013527 Rev02  04/19

Subject: K00459 S Model Bin Thermostat

FS9100 Assembly and Mounting

1. Move the ice machine and dispenser away from the

wall for easier access.

2. Remove panels and control box cover

3. If ice machine is on a dispenser:

A.

Remove 

fasteners

B.

Raise and support ice machine

4. Hook bracket onto adapter in position shown.

5. Secure bracket to adapter using screw provided.

6. Lower/place ice machine on dispenser and secure ice

machine to adapter with fasteners. It is important to
confirm that the ice maker is slid rearward contacting
the bracket and back spacer flange before re-fastening
(close gap).

FS9000 & FS9100 Continued

7. Route thermistor wire out towards the back of the

dispenser . Remove unused 7/8” diameter knockout on
the back panel, snap fit the bushing over the exposed
panel hole, and route wire into the ice machine control
board compartment. Internally the cable must be
routed as to avoid contact with high voltage, high heat,
or sharp objects.

8. Normally the controller can be mounted on the

bulkhead flange. If not, a suitable area must be found
for your model. Use controller bracket to locate
mounting holes on the flange of the bulkhead. Drill
two 9/32” diameter holes. Do not mount the controller,
at this time.

9. Route the four wires from the temperature control to

the control box (insuring that the wires  will not come
in contact with any refrigeration tubing).

Summary of Contents for FS9000

Page 1: ...00 or FS9100 FS9000 Assembly and Mounting 1 Move the ice machine and dispenser away from the wall for easier access 2 Bracket selection A Dual evaporator ice machines Use bracket with the shorter top flange B Single evaporator ice machines Use bracket with the longer top flange 3 Remove all panels and control box cover from the ice machine 4 If an ice machine is already installed on the dispenser ...

Page 2: ...nge before re fastening close gap FS9000 FS9100 Continued 7 Route thermistor wire out towards the back of the dispenser Remove unused 7 8 diameter knockout on the back panel snap fit the bushing over the exposed panel hole and route wire into the ice machine control board compartment Internally the cable must be routed as to avoid contact with high voltage high heat or sharp objects 8 Normally the...

Page 3: ... switch wire B Connect the white male bin switch wire to the white female wire of the controller KoolAire Models A Cut the red bin switch wire 3 inches from molex connector on bin switch B Strip wires and install male and female crimp connectors supplied in kit C Connect male and female connectors from the bin thermostat into the newly installed terminals 12 Restore all power to the ice machine an...

Page 4: ...e display then returns to the sensor temperature CHECK PROCEDURE If the control system does not function properly verify that the control is wired and set up properly If the problem persists use the following procedures to determine the cause of the problem nWarning Line voltage is present inside the control Contact with line voltage can cause injury or death Follow these troubleshooting procedure...

Page 5: ... the sensor leads and supply power to the control C Replace the cover D Check the control settings for proper values E Press and hold MENU until SP appears F Press up and down arrows to change the set point temperature above and below the sensor temperature until the relay energizes and de energizes G If the output relay does not perform as indicated replace the control H If proper operation of th...