2-4
Component Identification & Removal
Section 2
Spray Bar
The spray bar supplies water to the individual ice-making cups.
Water from the Water Pump sprays through the nozzles, located
on the upper portion of the tubes.
1.
Grasp one end of the spray bar, lift up and remove from
seat formed in water trough.
2.
Remove both plastic clips on water inlet tubing by grasping
both ears on clip and separating
3.
Apply food grade lubricate to ease re-assembly of spray bar
components when necessary.
4.
To re-install spray bar, position water inlet tubing on inlet
ports, and squeeze clips until tight.
5.
Reposition assembly on water trough seat.
Nozzles and inserts can be removed for cleaning by unscrewing
nozzles. Inserts are located inside the spray bar ports. The spray
bar also disassembles for easy cleaning.
Sump Drain Overflow Tube
The sump drain overflow tube is located in the evaporator water
sump.
1.
Remove shutters and ice chute.
2.
Lift spray bar or disconnect and remove for easiest access.
3.
Pull up on over flow tube to remove.
4.
To replace plug, insert in hole, and push with force to make
a tight seal.
OVERFLOW TUBE