Part Number 000015432 4/18
75
Hall Effect Switch Diagnostics
All diagnostics must be performed with the ice damper
installed and in the closed position. The control board
lights will not indicate as described below with the ice
damper in the open position. The ice damper must swing
freely, if the damper is binding adjust/loosen screws that
hold the Hall Effect switch housing in place.
SWITCH FAILS OPEN OR IS DISCONNECTED
HES#1
1. Reset line voltage to the ice machine
2. Wait 15 minutes for delay to expire.
3. HES#1 light energizes and ice machine starts.
4. When 15-minute delay period ends, the ice machine
shuts off and flashes the HES#1 light.
HES#2
1. Reset line voltage to the ice machine.
2. Wait 15 minutes for delay to expire.
3. HES#2 light is energized and HES#1 light is de-
energized.
4. Ice machine starts.
5. After 15 minutes the ice machine shuts off. HES#1 is
de-energized and HES#2 is energized.
Summary of Contents for CNF201A
Page 1: ...Part Number 000015432 4 18 Countertop Nugget Ice Machines CNF201 CNF202 Technician s Handbook ...
Page 2: ......
Page 20: ...20 Part Number 000015432 4 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 39: ...Part Number 000015432 4 18 39 Remove Screws ...
Page 42: ...42 Part Number 000015432 4 18 9 Lift out ice damper ...
Page 43: ...Part Number 000015432 4 18 43 10 Lift out ice strainer ramp ...
Page 44: ...44 Part Number 000015432 4 18 11 Turn ice wiper counterclockwise to remove ...
Page 100: ...100 Part Number 000015432 4 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 106: ...106 Part Number 000015432 4 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 113: ......
Page 114: ......
Page 115: ......