Part Number 000015432 4/18
87
DIAGNOSING START COMPONENTS
If the compressor attempts to start, or hums and trips the
overload protector, check the start components before
replacing the compressor.
Capacitor
Visual evidence of capacitor failure can include a bulged
terminal end or a ruptured membrane. Do not assume a
capacitor is good if no visual evidence is present. A good
test is to install a known good substitute capacitor. Use
a capacitor tester when checking a suspect capacitor.
Clip the bleed resistor off the capacitor terminals before
testing.
Relay
The relay has a set of contacts that connect and disconnect
the start capacitor from the compressor start winding. The
contacts on the relay are normally closed (start capacitor in
series with the start winding). The relay senses the voltage
generated by the start winding and opens the contacts as
the compressor motor starts. The contacts remain open
until the compressor is de-energized.
Summary of Contents for CNF201A
Page 1: ...Part Number 000015432 4 18 Countertop Nugget Ice Machines CNF201 CNF202 Technician s Handbook ...
Page 2: ......
Page 20: ...20 Part Number 000015432 4 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 39: ...Part Number 000015432 4 18 39 Remove Screws ...
Page 42: ...42 Part Number 000015432 4 18 9 Lift out ice damper ...
Page 43: ...Part Number 000015432 4 18 43 10 Lift out ice strainer ramp ...
Page 44: ...44 Part Number 000015432 4 18 11 Turn ice wiper counterclockwise to remove ...
Page 100: ...100 Part Number 000015432 4 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 106: ...106 Part Number 000015432 4 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 113: ......
Page 114: ......
Page 115: ......