5
1
2
[140mm]
41 [1040mm]
20
3
4
[527mm]
8
3
4
[222mm]
11
3
4
[298mm]
14
3
4
[375mm]
6 [154mm]
30 [763mm]
14 [357mm]
7
1
4
[185mm]
1
1
4
[35mm]
32
3
4
[833mm]
94 [2388mm]
Dr
iv
e
Uni
t
75
1
2
[1918mm]
2
1
2
[61mm]
62
1
2
[1590mm]
34 [864mm]
29 [737mm]
8
1
2
[218mm]
21 [533mm]
25 [635mm]
12 [307mm]
1 [25mm]
25 [635mm]
10 [254mm]
C
B
A
M
4 [102mm]
24 [609mm]
45
3
4
[1161mm]
L
A
102 [2591mm]
23
1
2
[598mm]
6 [152mm]
7 [178mm]
D
E
B
33
1
2
[851mm]
8 [206mm]
Dr
iv
e
Uni
t
1
2
[15mm]
84 [2134mm]
B
A
M
L
Dis
h Clear
anc
e
W
ith Door
s
O
pen
Rear
of
Mac
h
ine
14 [356mm]
Mi
n
imu
m
10"
H
igh
Tabl
e
B
a
cksplash
Sc
ra
p
Trough
6 [152mm]
T
able to T
able
O
v
er
all
36 [914mm]
31
1
4
[795mm]
6
1
2
[165mm]
26
1
2
[673mm]
6 [152mm]
Left Side
Front View
R
ight Side
C
F
loor
Sink
O
r Dr
ain
W
ith 3" (
76 mm)
Minimum Dr
ain Line
4" (
102 mm)
wide x
16" (
406 mm)
long c
utout in Vent Cowl/Splas
h
Shield. Shipped with Cov
e
r Plate.
Mi
n
imu
m
Scrap
T
rough
14 [355mm]
25 [635mm]
21 [533mm]
8 [203mm]
64 [1626mm]
22 [559mm]
Bas
e
U
n
it
Pr
ewas
h
F
Left to R
ight
Legend
A -
Mac
hine water
inlet 3/4" NPT
, 180°F
Hi-
temp,140°F
Low-
temp minimum
B -
Elec
tr
ic
al c
onnec
tion
C -
Dr
ain c
onnec
tion 1-
1/2" NPT
D -
Vent c
ollar
-
O
ptional
E -
Vent c
owl s
tandar
d
F
-
3/4" NPT
180°F
W
a
ter
Inlet for
was
h
tank
fill, final r
ins
e, & tank heating. F
rom gas
boos
ter
heater
. Inter
c
onnec
ting hos
e
pr
ov
ided by
manufac
tur
er
.
G
-
3/4" NPT
140°F
W
ater
inlet for
gas
boos
ter
heater
.
H -
3/4" NPT
180°F
W
a
ter
O
u
tlet
c
onnec
tion to line on dis
hmac
hine.
Connec
tion hos
e pr
ov
ided by
manufac
tur
e
r.
J
-
3/4" NPT
G
as
Connec
tion
K -
4" O
D
Vent pipe c
onnec
tion. F
lue to
be ins
talled to meet loc
al c
odes
by
ins
talling c
ontr
ac
tor
.
L -
Pr
ewas
h water
inlet 3/4" NPT
110°F
-140°F
M -
Cold water
ther
mos
tat plumbing
c
onnec
tion 3/4" NPT
-
O
ptional
Note: All v
er
tic
al dimens
ions
ar
e +/-
1/2" fr
om
floor
due to adjus
table bullet feet.
86 [2184mm]
H
G
J
K
H
G
J
K
66
1
2
[1692mm]
65
1
2
[1666mm]
Pr
ewas
h Plan View Sec
tion
wi
th Col
d
W
a
ter
T
her
mos
tat
16
3
4
[425mm]
16
1
4
[415mm]
L
M
3/4" [19 mm]
T
able T
ur
ndown
F
lange 3/4" Max
21" [533 mm]
Rac
k
Rai
l Hei
ght
Abov
e Dis
h
table
1/4" [6mm] -
5/16" [8mm]
Rac
k
Rai
l
Tu
b
T
able
U
s
e Silic
one Sealer
Between T
able and
Lip of Mac
hine to
Pr
ev
ent Leak
age
Recommended Table Fabr
ication
N
o
te
: T
ub W
ill Ac
cept
a T
able F
lange
Up to 24 7/8"
[632 mm]
SECTION 1: SPECIFICATION INFORMATION
AJ-86 GAS - LEFT TO RIGHT
13
AJ-64 Conveyor Series Technical Manual 7610-003-30-93
Issued: 05-02-2006 Revised: 09-29-2007