Dr
iv
e
Un
it
60
1
4
[
1530m
m]
62
1
2
[
1590m
m]
29 [
737mm]
6 [
152m
m]
10 [
254mm]
4 [
102m
m]
7 [
178m
m]
D
E
8 [
203m
m]
L
24 [
610mm]
M
23
1
2
[
599mm]
10
1
4
[
261mm]
47 [
1194m
m]
A
53
3
4
[
1365m
m]
B
C
43 [
1092m
m]
75
1
2
[
1919m
m]
6 [
155m
m]
36 [
914mm]
31
1
4
[
797mm]
6
1
2
[
165mm]
26
1
2
[
673mm]
Fr
ont
V
ie
w
3/
4" [
19 mm]
T
able T
urndown
F
lange 3/
4" M
a
x
21" [
533 mm]
Rac
k
Rail Height
A
bov
e Dis
ht
able
1/
4" [
6
mm
] - 5/
16" [
8
mm]
Rac
k
Rail
Tu
b
T
able
Us
e S
ilic
one S
ealer
B
et
w
een T
able and
Lip of
Mac
hine t
o
P
rev
ent
Leak
age
Recommended Table Fabr
ication
Note: T
ub W
ill A
c
c
ept
a T
able F
lange
Up t
o 24 7/
8"
[632 mm]
R
ight to Left
Legend t
o Drawing
A
-
M
a
c
h
ine wat
e
r inlet
3/
4" NP
T
, 180°F
Hi-
tem
p,
140°F
Low-t
emp minimum
B
-
E
lec
tr
ic
al c
onnec
tion
C -
Drain c
onnec
ti
on 1-
1/
2" NPT
D -
V
ent
c
ollar
-
O
pt
ional
E
-
V
ent
c
owl s
tandard
F
-
3/
4" NP
T
180°F
W
at
er I
nlet
f
or was
h t
ank
f
ill,
f
inal rins
e,
&
t
ank
heat
ing.
F
rom gas
boos
te
r heat
er
. I
n
te
rc
onnec
ti
ng hos
e
pr
ov
ided by
manuf
ac
tu
rer.
G
-
3/
4" NP
T
140°F
W
at
er inlet
f
or
gas
boos
te
r heat
er.
H -
3/
4" NP
T
180°F
W
at
er O
ut
let
c
onnec
ti
on t
o line on dis
hmac
hine.
Connec
ti
on hos
e pr
ov
ided by
manuf
ac
tu
rer.
J
-
3/
4" NP
T
G
as
Connec
tion
K
-
4" O
D V
ent
pipe c
onnec
tion.
F
lue t
o
be ins
talled t
o meet
loc
al c
odes
by
ins
talling c
ont
rac
tor.
L -
P
rewas
h wat
er
inlet
3/
4" NPT
110°F
-140°F
M
-
Cold wat
er
t
hermos
tat
plumbing
c
onnec
ti
on 3/
4" NPT
-
O
pt
ional
Not
e:
A
ll v
er
tic
al dimens
ions
are +/
- 1/
2" f
rom
fl
oor
due t
o adjus
table bullet
f
eet
.
T
able t
o T
able
O
v
erall
4" (102 m
m
) wide x
16" (406 mm)
long c
ut
out
in Vent
Cowl/
Splas
h
S
hield.
S
hipped wit
h Cov
er Plat
e.
86 [2182m
m
]
94 [2386m
m
]
102 [2589m
m
]
B
F
loor
S
ink
O
r Drain
W
it
h
3" (
76 mm)
M
inim
um
Dr
ain Line
25 [
637mm]
8 [204m
m
]
21 [535m
m
]
20
3
4
[527m
m
]
8
3
4
[222m
m
]
11
3
4
[298m
m
]
14
3
4
[375m
m
]
6 [
152m
m]
30 [
763mm]
14 [
357mm]
7
1
4
[
185mm]
1
1
4
[
35m
m]
K
J
H
G
A
P
rewas
h P
lan View S
ec
tion
wit
h Cold W
a
te
r T
hermos
tat
16
3
4
[
425mm]
16
1
4
[
415mm]
L
M
22 [557m
m
]
64 [1626m
m
]
B
a
s
e
Unit
P
rewas
h
K
J
H
G
C
Ri
ght
S
id
e
34 [
864mm]
8
1
2
[
217mm]
21 [
533mm]
25 [
635mm]
12 [
307mm]
25 [
635mm]
B
Dis
h Clearanc
e
Dr
iv
e
Un
it
L
e
ft Side
66
1
2
[
1692m
m]
3 [
79mm]
1
2
[
15m
m]
84 [
2134m
m]
A
M
L
W
it
h Door
s
O
pen
Rear of
Ma
ch
in
e
6 [
152m
m]
1 [
25mm]
65
1
2
[
1665m
m]
SECTION 1: SPECIFICATION INFORMATION
AJ-86 GAS - RIGHT TO LEFT
14
AJ-64 Conveyor Series Technical Manual 7610-003-30-93
Issued: 05-02-2006 Revised: 09-29-2007