![Manitowoc 999 Service And Maintenance Manual Download Page 270](http://html.mh-extra.com/html/manitowoc/999/999_service-and-maintenance-manual_701168270.webp)
Reference
Only
TROUBLESHOOTING
999 SERVICE/MAINTENANCE MANUAL
10-34
Published 05-16-17, Control # 233-03
Test 3 – Checking Resistance at Engine Oil Pressure Sender
Set digital multi-meter to test resistance. Make required
connections to test lead adapter at the meter. Connect
negative lead to a grounded component on the crane and
the positive lead to engine pressure sender wire terminal.
With engine cold, check for a resistance of approximately
240 ohms.
Item
Description
1
Oil Pressure Sender
1
P1590