32
Wireless Linear CCD Barcode Scanner
Follow the steps below to set a fixed length:
1. Scan the barcode containing “Begin” for the desired set.
2. Refer to the Decimal Value Tables in Appendix A. Scan
the label(s) that represent the length to be read.
3. Scan the barcode containing “Complete” for the
desired set.
Repeat steps one through three to set additional lengths.
Set Up Code Length
%4K1+
<Variable>
Fix Length (Two Sets Available)
2. Scan Decimal Value
(Appendix A)
1. Begin 1st Set
%4K00
3. Complete 1st Set
%4K01
1. Begin 2nd Set
%4K00
2. Scan Decimal Value
(Appendix A)
3. Complete 2nd Set
%4K02
Minimum Length
1. Begin
%2+-/
2. Scan Decimal Value
(Appendix A)
3. Complete
%2C6
Code 11 Parameters
Check Digit Transmission
Do Not Calculate
Check Digit
%0LN3
<Calculate Check 1 Digit
and Transmit>
%0LN7